The ceiling fan must be installed in a location so that the blades are 300mm spacing from the tip of
the blade to the nearest objects or walls.
Secure the hanging bracket to the ceiling joist or structure that is capable of carrying a load of at
least 40KG, with two long screws provided. Ensure at least 30mm of the screw is threaded into the
support.
NOTE: The bracket screws provided are for use with wooden structures only. For structures
other than wood, the appropriate screw type MUST be used.
Angled Ceiling Installation
This fan hanging system supports a maximum
20 degree angled ceiling installation.
INSTALLING THE MOUNTING BRACKET
Fig. 3