Programming The Start Up Of The Self-Cleaning System For The Tecno Star Dual Power Unit (See Tecno Star Dual Power Manual) - Sistem-Air Autocleaner Manual Tecnico

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

11.1.1 Programming the start up of the self-cleaning system for the TECNO
Star Dual power unit (see TECNO Star Dual Power Manual)
Engine:
Depression:
Filter e .:
Dust bin level:
Press ENTER
MAIN MENÙ
Turbo function
Adjust Date/Time
Info/Alarms
Set Alarms policies
INSTALLATION PARAM.
Data transmission
Reset parameters
Test function
AUTOCLEANER SYSTEM
Function active
Cycles number
Working
Autoclean.Timer
05/07/11 Rev:1.0.0
26-07-11
10:00
OFF
0 mbar
100%
0%
<OFF>
< 1>
<12h>
<15h>
Main Menu
1
1
Press ENTER to move onto the main Menu.
Use the up and down arrows to select
2
1
INSTALLATION PARAM. Press ENTER
to move onto the submenu.
Activate the control of the Autocleaner
3
1
system (optional accessory):
ACTIVE FUNCTION:
OFF: the Autocleaner system is not con-
nected to the vacuum unit.
ON: the Autocleaner system is connec-
ted to the vacuum unit.
NR. OF CYCLES: selection of the num-
ber of cycles of the Autocleaner system
activated continually.
FUNCTIONING:
12 h: permission to activate the Autoclea-
ner system from 8 to 20.
24 h: permission to activate the Autoclea-
ner system 24/7
Autocleaner Timer: time in hours to start
automatically the cleaning cycles of the
fi lter.
Press ENTER to save.
Press ESC to move onto the Main Menu.
2 2