NAME OF PARTS AND OPERATION SELECTOR
INDOOR UNIT
3
4
2
1
1. Remote control unit.
2. Sensor: Detects the room temperature around the remote
control unit, the air conditioner is controlled accordingly.
3. Air outlet: Conditioned air is blown out of the air conditioner
through the air outlet.
4. Air intake: Air from the room is drawn into this section and passes
through air filter which removes dust.5.
receiver: This section picks up infrared signals from the remote
control unit (Transmitter).
6. Operation selector.
ON Position:
In this position the air conditioner is operating
and controlled by the remote control unit.
Set the selector normally in this position.
OFF Position:
Switch the selector to the off position if you
are not going to use the air conditioner for
a few days or longer.
WARNING
The OFF position does not disconnect the power. Use the
main power switch to turn off power completely.
CAUTION
TEST Position:
This position is used only for servicing the
air conditioner, so don't leave the selector in
this position for normal operation.
7. OPERATION lamp: This lamp lights when the air conditioner
is running.
8. STANDBY lamp: This lamp lights
– During warm up period
– When the system is defrosting
– When the temperature selected on the remote control unit is
reached
This lamp switches off automatically
– At the end of defrosting period
– At the end of warm up period
To keep a constant room temperature, the air conditioner continues
to supply a gentle breeze during warm up or when the heating
operation is interrupted by the thermostat (heat pump version).
9. TIMER lamp: This lamp lights when the system is being
controlled by the timer.
5
COOLING Model Only
9
7
COOL / DRY / HEAT Model Only
9
7
5
8
INSTALLATION LOCATION
We recommend this air conditioner to be installed properly
by qualified installation technicians in accordance with the
installation instructions provided with the unit.
Remote control
Avoid:
To protect the air conditioner from heavy corrosion, avoid installing
the outdoor unit where salty sea water can splash directly onto
it or in sulphurous air near a spa.
ELETRICAL REQUIREMENTS
APPLICABLE ONLY FOR MODELS
GR/GRV18X - GR/GRV22X
If the air conditioner hasn't been used for a long
period, warm up the system, the power mains must
be turned on at least five (5) hours before operation.
3
5
WARNING
Do not install this air conditioner where there are fumes
or flammable gases, or in an extremely humid space
such as a green house.
Do not install the air conditioner where excessively high
heat-generating objects are placed.
Do not install the air conditioner where the atmosphere
is extremely damp or humid (e.g. greenhouse or laundry)
it could be wetted by drops of water (i.e. in laundries).
Before installation, check that the voltage of the electric supply
in your home or office is the same as the voltage shown on the
nameplate.
All wiring must conform to the local electrical codes. Consult
your dealer or a qualified electrician for details.
Each unit must be properly grounded with a ground (or earth)
wire or through the supply wiring.
Wiring must be done by a qualified electrician.
CAUTION
POWER MAIN SWITCH
EG
6
OFF
ON
TEST