Part no
6159943830
Issue no
02
Series no
B
Date
10/2008
Page
8 / 44
This product is designed for removing
material using abrasives. No other use
permitted. For professional use only. Before
servicing the power tool, the supply of compressed
air must be disconnected or shut off.
When disposing of components, lubricants,
e t c . , e n s u r e t h a t t h e r e l e v a n t s a f e t y
procedures are carried out.
The tool is designed for a working pressure of
6.3 bar (90 psig). The compressed air must
b e c l e a n . T h e i n s t a l l a t i o n o f a f i l t e r i s
recommended. For maximum efficiency and
performance, comply with the specification of the
air hose (antistatic hose). (Refer to figure no.1 for
compressed air connection)
ømini mm = 10 (3/8")
To obtain maximum efficiency from the
pneumatic tool, preserve its features and
avoid repeated repairs, a routine inspection and
repair programme are recommended at least every
2,000 hours, the intervals between the various
inspections depending on the amount of exertion
on the power tool.
• Disassemble the tool, clean the parts with
petroleum and check them carefully.
• Lubricate and reassemble the unit.
T h e h a m m e r w i l l b e l u b r i c a t e d w i t h
BARTRAN 22 type oil. To ensure proper
lubrication, the use of a lubricator / regulating
filter is recommended. It shall be positioned above
or at the same level as the work station. Daily check
the oil level in the lubricator and oil flow adjustment.
For easier tool start-up at low temperatures, we
recommend mixing 10% petroleum with the
lubricating oil.
1
B20-00 – B20-0 – B20 – B20-1
INSTRUCTIONS
7 m max.
© Copyright 2008, Desoutter St Herblain France
All rights reserved. Any unauthorized use or
copying of the contents or part thereof is prohibited.
This applies in particular to trademarks, model
denominations, part numbers and drawings. Use
only authorized parts. Any damage or malfunction
caused by the use of unauthorised parts is not
covered by Warranty or Product Liability.
2