13. MAINTENANCE

For all Whale Twist® models
Clean housing and handset with warm soapy water.
Do not use any chemical cleaning agents.
Regular inspection of plumbing connections and tubing is recommended.
For Mixer Models
If you need to remove the handset and hose for replacement, remove the unit at the
valve housing and insert the temporary shut off valve as shown. (See Fig. 16a, 16b and
16c). This allows you to use the freshwater system until the new hose is installed.
Fig. 16a

14. INSTRUCTIONS FOR USE

STEP 1 Pull handset gently from the housing. (See Fig. 17)
STEP 2 Set flow / temperature. (Temperature settings do not apply for cold only
models). Twist handset to desired flow / temperature setting. (See Fig. 18)
CAUTION: For health and safety reasons, temperature should be set at 38ºC (100
ºF). Higher settings will increase the risk of scald injury. Those at greatest risk of scald
injury include children, the elderly, disabled, and diabetics.
Fig. 17
Fig. 16b
Fig. 18
Fig. 16c
Temperature / flow indictor
9