STEP 3 Enjoy showering.
After Use
STEP 1 Twist upper part of handset to the 'off' position.
Note: Ensure handset is fully closed before stowage.
STEP 2 Replace handset in holder.

15. TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
Limited flow Blocked shower nozzles
Pump may not be
No flow
operating. Valve housing
is not in 'On' position

16. WINTERIZING

Freezing in winter may cause damage to the Whale Twist® Deck Shower.
To avoid this damage, ensure the system is completely drained.
1.
Drain the fresh water tank either using the pump or a drain valve.
2.
Turn pump on and open all faucets (including drain valve) and allow the pump
to purge the water from the system.
3.
Open the Whale Twist® Deck Shower until water flow stops.
4.
Turn off Whale Twist® Deck Shower.
5.
Turn off power isolator switch for water pump.
6.
Remember to leave all outlets open except Whale Twist® Deck Shower
to avoid any damage.

17. SERVICE SUPPORT DETAILS

For installation or service advice please contact Whale support:
Tel: +44 (0)28 9127 0531
USA Tel: +1 616 897 9241
Please note: The Whale Twist® Deck Shower hose should be replaced after every 5
years of use.
POSSIBLE SOLUTION
Check for any blockages in the handset.
Clean head with warm soapy water (do not
use any chemical cleaning agents)
Check pump is operating. Check valve
housing is in locked 'on' position (See Fig.
14)