 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
 Clean the external optics at least once every 30 days.
 Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
Max Power consumption:
Sound Control:
Pan/Tilt:
Beam angle:
DMX connections:
Leds:
Size:
Weight:
You can download the latest version of this user manual on our website: www.beglec.com
BRITEQ
®
AC 100 - 240V, 50/60Hz
138 Watt
Internal microphone
540° / 270°
15°
3pin XLR male / female
1 White LED 70Watt
See drawing
9 kg