5.1 Product group 605056, HFT = 0, IPL 1:
II 2 G Ex d
Standard designation according to standard series EN 60079 for electrical devices:
"d": Operating equipment with ignition protection type "d" pressure resistant enclosure
Standard designation
Category according to ATEX standard 2014/34/EU
G: gas explosion protection
Operating equipment for category 2 with pressure resistant enclosure "d" according to EN 60079-1
Identification markings for device group II acc. to guideline (non-firedamp endangered mine workings)
Identification marking explosion protected device according to ATEX directive 2014/34/EC
II (2) G [Ex e]
II (2) G [Ex d]
II (2) D [Ex tb]
e: Temperature limit for a piece of operating equipment with ignition protection type,
Advanced safety Ex e
d: Temperature monitoring of a bearing passage on an enclosure with the ignition protection type,
pressure resistant enclosure Ex d
tb: Temperature monitoring of a piece of electrical operating equipment with the ignition protection type;
Equipment dust explosion protection through enclosure Ex
Safety equipment acc. to EN 50495 for Cat. 2G or 2D Dir. 2014/34/EU,
Application for ignition protection type
Pressure resistant enclosure "d" acc. to EN 60079-1 and advanced safety "e" acc. to EN 60079-7(gas),
Protection through enclosure "t" acc. to EN 60079-31, equipment protection level "tb" (dust)
II (2) G (b2)
II (2) D (b2)
Standard designation as per the EN 13463 series of standards for non-electrical devices:
"b1": Ignition source monitoring acc. to EN 13463-6 with IPL 1 for Cat. 2
"b2": Ignition source monitoring acc. to EN 13463-6 with IPL 2 for Cat. 2 (redundant use)
Safety device according to EN 13463-6 for category 2 applications for ignition protection
ignition source monitoring of non-electrical ignition dangers "b" according to EN 13463-6
Categories acc. to ATEX Directive 2014/34/EU
G: Gas explosion protection; D: Dust explosion protection
IIC Gb
"EPL" (Equipment Protection Level)
Gb (gases) for category 2
Standard designation according to EN 60079-0
Explosion group IIC
Gases, low ignition energy such as hydrogen
acc. to EN 60079-1 for Cat. 2
Safety equipment electrical ignition protection, example of standard designation
acc. to EN 50495, depending on the respective ignition protection of the EUC,
with SIL 2 and HFT 0
Category (Cat. 2),
through redundant use, even with SIL 2 and HFT 1 Category 1
Safety equipment non-electrical ignition protection
Caution: Redundant use only!
Safety Manual
(device's inherent ignition protection)