INSTALLATION INSTRUCTIONS

TECHNICAL DATA
MODELS
Voltage
Current
Induction plate 2200W /Booster 3000W
Induction plate 1400W
Max power W
1.Installation (Fig 1)
Installation is the buyer's responsibility. The manufacturer accepts no liability for this service. Any action that the
manufacturer has to take due to an erroneous installation will not be covered by the guarantee.
The flush-mounted cook tops are designed for installation in work tops made of all kinds of material, providing they
can withstand a temperature of 100°C, and are between 25 and 40 mm thick. If the cook top is installed in a
position so that the side of a kitchen unit comes up against its left-hand or right-hand side, the distance between
the vertical panel and the edge of the cook top must always be at least 150 mm. The distance between the back
wall and the edge of the cook top must be at least 55 mm. A partition made of insulating material (wood or the
like) must be inserted between the cook top and the space below. This partition must be at least 25 mm from the
underside of the cook top tray.
Fixing the cook top to the unit (Fig 2)
The cook top is fixed to the unit by means of the brackets and accessories provided. Holes are provided in the
bottom of the tray so that you can attach the screws (C) that hold the brackets (B) in place.
Applying the seal (Fig 3)
Important - The figure shows how the seal must be attached all around the perimeter.
This cook top has been designed for non-professional, domestic use.
Coupling two or more Domino cook tops (Fig 4)
Cut out the work top to allow for the flush mounting of two or more Domino cook tops.
First of all, place the steel supporting element (E) provided in the package in position, then insert the cook top (G)
as illustrated in the figure below. Insert the second cook top (F) in the remaining space.
Together with the seal on the two Domino cook tops, the steel support will ensure that the top is watertight.
The Domino cook tops are fixed to the work top using the kit of brackets provided.
Between the hob and any exhaust hood it must be a distance of 70 cm at least.
2.Electric connections
Check the details given on the nameplate situated on the underside of the cook top, then make sure that the rated
mains voltage and power available are suitable for its operation.
Before making the electric connections, check the efficiency of the earthing system. Earthing of the cook top is
compulsory by law. The manufacturer will accept no liability for any personal injury or damage to property deriving
from failure to comply with this requirement.
For models without a plug, fit a standard plug capable of withstanding the specified load on the power cord. The
cord's earthing conductor is colored yellow and green. The plug must be accessible.
If you prefer to make a fixed connection to the mains, insert an all-pole circuit breaker with a breaking gap of at
least 3 mm between the cook top and the mains.
To connect the cook top power cord, loosen and remove the cover on the terminal block in order to access the
contacts inside. Make the connection, blocking the cord in place with the cable clamp provided and then close the
terminal block cover again immediately.
If you have to change the cord, the earthing (yellow / green) conductor must always be 10 mm longer than the line
conductors.
Use only rubber cable type H05RR-F.
DECLARATION OF CONFORMITY
This appliance, in the parts intended to come into contact with food, complies with the requirement of the Directive
89/109 EEC and the D.L. Implementing No. 108, 25/01/92; replaced by Regulation 1935/2004/EC.
This appliance complies with the requirement of the European Directive 73/23/CEE and 89/336/CEE, replaced by
2006/95/CE e 204/108/CE and following modifications and also to the European directive No. 93/68/CEE.
ATTENTION: If you need to replace the power cord, be sure to respect the following code-colour during the
connection of individual wires:
HVI32
230V
16
1
1
3.6KW