5. Specifications

5.1 Environmental specifications

5.2 Electrical & mechanical specifications

5.3 Fuses

Operating temperature:
Operating relative humidity:
Altitude:
Storage temperature:
Storage relative humidity:
Mains input voltage (single-phase) 220-240 VAC / 50-60 Hz
Power consumption at full load
Maximum primary current @ 195 V 4A
Protection Class
Neutral and earthing systems
Mains circuit breaker
Rated output voltage
Floating voltage (half load)
Maximum output current
(total for all 9 outputs)
Main outputs (6)
Auxiliary outputs (3)
Rated output current (without
reducing battery capacity)
Dimensions (wxhxd)
Weight
F1 Mother board (AC mains input)
F8 Mother board (to battery)
F1 to F6 main outputs
Faux1 to Faux3 auxiliary outputs
External Battery fuse (not included) Ib max (when mains not present), type gG
-5 °C to +45 °C at 12A
20 to 95 % without condensation
> over 2000 m. Max operating temperature decreases 5°C
every 1000 m. Cooling operates transversally.
-25 to +85 °C.
10 to 95 %.
760 W
Class 1
TT, TN, IT
two pole circuit breaker (D curve) to be provided upstream
48 VDC
54.4 VDC +/-0.5%
150A total
40A max.
5A max.
12A max.
483 x 44.5 x 310 mm (19",2U high)
6 kg
8A, type: T(slow), breaking capacity 1500A, size: 5x20
12.5A, type: T (slow), size: 5x20
32A, type: gG, size: 10x38
5A, type: F (fast), size: 5x20