Safety notes

Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.

Technical data

• Max. flow:
0.8 L/cycle or 0.2 gpc / 0.41 MPa (60 psi)
• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
• Hot water supply temperature:
Recommended (energy economy):
Thermal disinfection possible.
Fitting with battery:
• Voltage supply:
Fitting with switched-mode power supply (42 464):
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
• Automatic safety shut-off
(6 - 420 s adjustable):
• Run-on time (0 - 19 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (adjustable):
• Type of fitting protection:
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
1
English
0.05 MPa (7.25 psi)
0.1 - 0.5 MPa (14.5 - 72.5 psi)
max. 1 MPa (145 psi)
1.6 MPa (232 psi)
max. 158 °F
140 °F
6V lithium battery type CR-P2
2.4 W
11 s
1 s
approx. 5"
IP 59K
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa (72.5 psi), a pressure-
reducing valve must be installed.
Functions, programme selection,
see technical product information,
www.grohe.com/tpi/euroeco-ce
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
, see fold-out page I and II.
Flush piping system prior and after installation of
fitting thoroughly!
Open cold and hot water supply and check
connections for leakage.
Maintenance
, see fold-out page II.
• Shut off hot and cold water supply.
• Disconnect voltage supply.
• Inspect and clean all components and replace if
necessary.
Replacement parts
see fold-out page I (* = special accessories)
,
Care
For directions on the care of this fitting, please refer
to the accompanying Care Instructions.
Remedy
- Clean or replace filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
A
2
2500 V
100 °C