Enable Zone And Safe Switch Off Distance; Fig. 1: Schematic Illustration Of The Zones Of The In4000 Standard Safety Switches (Based On The Example Of The In40-D0101K) - SICK IN4000 Standard Manual Del Operador

Ocultar thumbs Ver también para IN4000 Standard:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3
Chapter
Fig. 1:
Schematic
illustration of the
zones of the
IN4000
Standard safety
switches (based
on the example
of the
IN40-D0101K)
156
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8010934/WQ88/2013-01-15
Product description
IN4000 Standard series safety switches can be
cascaded. Information on this topic is to be found in
the operating instructions for the evaluation device
used (e.g. Flexi Classic or Flexi Soft).
3.3
Enable zone and safe switch off
distance
Near range
Sensor
The output of the safety switch is only enabled on
activation within the enable zone. Outside the enable
zone, that is also in the near range, the output
remains switched off.
After activation in the near range, either the power
supply must be interrupted or the actuating element
must be placed at the safe switch off distance for
more than 2 s before enable is possible again.
The enable zone is dependent on the type of safety
switch and the material and shape of the actuating
element. The use of different actuating elements
(material, shape) will result in different enable zones.
Enable zone
Safe switch off distance
Operating Instructions
IN4000 Standard
Actuating object
(metal)
Distance

Publicidad

Tabla de contenido
loading

Tabla de contenido