In40-D0202K Safety Switches - SICK IN4000 Standard Manual Del Operador

Ocultar thumbs Ver también para IN4000 Standard:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4
Chapter
WARNING
172
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8010934/WQ88/2013-01-15
Mounting
4.2
Mounting the IN40@D03.. and

IN40-D0202K safety switches

The IN40-D0303K and IN40-D0202K safety switches
are not allowed to be mounted flush.
The IN40-D0303K safety switch is not allowed to be
mounted flush; this type of mounting results in the
categorisation I2A18SP2M as per EN 60947<5-2.
The IN40-D0202K safety switch is not allowed to be
mounted flush; this type of mounting results in the
categorisation I2A30SP2M as per EN 60947<5-2.
Flush installation is allowable using IN40-D0304K
safety switch: this type of mounting results in the
classification I2A18SP2M as per EN 60947-5-2.
Pay attention to safe switch off distance and enable
zone (cf. Tab. 2, Tab. 3 and Tab. 4).
The minimum distances stated in Fig. 6, Fig. 7 and
Fig. 8 for neighbouring sensors, sensors mounted
opposite and the minimum distances to fixed parts
of the plant and walls must be observed.
Operating Instructions
IN4000 Standard

Publicidad

Tabla de contenido
loading

Tabla de contenido