SAMES KREMLIN SLR S-BOX Manual De Explotación página 44

Tabla de contenido

Publicidad

102
Oht.r
Rectifier over temperature
103-
rES
Spare
108
Power module over current
109
OI.dc
detected from IGBT on state
voltage monitoring
110-
rES
Spare
172
173
FAN.F
Fan fail
174
C.SI
NV Media Card trip; Option
module file transfer has failed
NV Media Card data blocks
175
C.Pr
are not compatible with the
drive derivative
176
rES
Spare
The Menu 0 parameter modi-
177
C.bt
fication cannot be saved to
the NV Media Card
NV Media Card cannot be
accessed as it is being
178
C.by
accessed by an option mod-
ule
NV Media Card data loca-
179
C.d.E
tion already contains data
NV Media Card trip; option
modules installed are differ-
180
C.OPt
ent between source drive
and destination drive
NV Media Card has the Read
181
C.rdo
Only bit set
NV Media Card data struc-
182
C.Err
ture error
NV Media Card data not
183
C.dAT
found
184
C.Ful
NV Media Card full
185
C.Acc
NV Media Card Write fail
NV Media Card Trip; The volt-
age and / or current rating of
186
C.rtg
the source and destination
drives are different
Indice de revisión : E - Julio de 2017
• Check the motor and motor cable insulation with
an insulation tester
• Fit an output line reactor or sinusoidal filter
• Force the heatsink fans to run at maximum speed
by setting Pr 06.045 = 1
• Check enclosure / drive fans are still functioning
correctly
• Check enclosure ventilation paths
• Increase acceleration / deceleration rates
• Reduce duty cycle
• Reduce motor load
The short circuit protection for the drive output
stage has been activated.
• Disconnect the motor cable at the drive end and
check the motor and cable insulation with an insu-
lation tester
• Replace the drive
• Check that the fan is fitted and connected cor-
rectly.
• Check that the fan is not obstructed.
• Contact the supplier of the drive to replace the
fan
44
6424

Publicidad

Tabla de contenido
loading

Tabla de contenido