Analog Output Lambda/Afr X Voltage Table - FuelTech ALCOHOL-O2 Manual De Instalación Y Especificaciones Técnicas

Condicionador de sonda de banda ancha de alta precisión
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.4 Analog output Lambda/AFR x Voltage table

Voltage (V)
0.048
0.521
0.765
1.003
1.145
1.287
1.430
1.549
1.657
1.763
1.882
2.000
2.094
2.190
2.285
2.380
2.427
2.475
2.523
2.569
2.617
2.665
2.711
2.736
2.760
2.783
2.808
2.854
2.902
2.973
3.006
AFR (Gasoline)
4.120
6.470
7.640
8.530
9.260
10.000
10.580
11.170
11.760
12.500
13.380
14.700
16.320
18.380
21.020
24.400
26.460
28.960
32.050
35.720
40.430
46.310
53.950
59.240
65.420
72.770
82.320
110.250
167.870
343.250
470.400
AFR (Alcohol)
1.800
2.820
3.340
3.720
4.040
4.370
4.620
4.880
5.140
5.460
5.840
6.420
7.130
8.030
9.180
10.660
11.560
12.650
14.000
15.600
17.660
20.220
23.560
25.870
28.570
31.780
35.950
48.150
73.320
149.910
205.440
Alcohol - O2
Lambda
0,280
0,440
0,520
0,580
0,630
0,680
0,720
EN
0,760
0,800
0,850
0,910
1,000
1,110
1,250
1,430
1,660
1,800
1,970
2,180
2,430
2,750
3,150
3,670
4,030
4,450
4,950
5,600
7,500
11,420
23,350
32,000
9