8. DISPLAY ERRORS
GB
See B ill. 3
ERROR
E0
1. The "ON/OFF" switch is turned "ON" (|)
when the generator is plugged in
E1
1. No fuel
2. Fuel is contaminated
3. Photocell is dirty or damaged
4. Fuel fi lter is dirty
5. Ignition error
E2
1. Terminal disconnected
2. Sensor is damaged
E3
1. Internal generator overheating
LO
1. External temperature below -9°C
HI
1. External temperature above +50°C
OF
1. Control apparatus blocked
9. PREVENTIVE MAINTENANCE SCHEDULE
WARNING: BEFOR INITIATING ANY REPAIR OR MAINTENANCE PROCEDURE UNPLUG THE
FEEDER CABLE AND MAKE SURE THAT THE GENERATOR IS COOLED DOWN.
COMPONENT
Fuel tank
Nozzle
Photocell
Fuel fi lter
Ignition device
Fan blades
CAUSE
TEMPERATURE CONTROL SENSOR ERROR
MAINTENANCE FREQUENCY
Clean every 150-200 hours of operation
or when necessary
Clean or replace once per season or
when necessary
Clean once per season or when
necessary
Clean or replace twice per season or
when necessary
Clean or replace every 1.000 hours of
operation, or when necessary
Clean when necessary
OPERATION ERROR
1. After disconnecting the generator, see that
the switch is in the "OFF" (0) position, plug
the generator in and turn the switch "ON" (|)
PHOTOCELL ERROR
1. Turn the switch "OFF" (0), refi ll the fuel tank
2. Turn the switch "OFF" (0) empty and refi ll the
fuel tank. Clean the fi lter using clean fuel, do
not damage the fi lter (SEE PARA. 6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
1. Connect the terminal
2. Contact the technical service center
THERMOSTAT ERROR
1. Turn the generator off, wait until it is cooled
down
1. Normal condition
1. Normal condition
1. Restart the generator
MAINTENANCE PROCEDURE
Empty and rinse with fresh fuel
Contact the technical service center
Contact the technical service center
Clean the fuel fi lter with clean fuel
Contact the technical service center
Contact the technical service center
SOLUTION