2.
Clean impeller and all accessible
inside
surfaces
of
Remove any fibres which may have
wound around the impeller shaft.
Remove
persistant
brush and dishwashing liquid.
3.
Reassemble pump.
7.2
Pump storage
A
Caution!
Frost damages the pump and
accessories, as both always contain
water!
When there is danger of freezing
remove pump and accessories and
store at a frost-proof location.
8. Trouble Shooting
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
8.1
Fault finding
Pump does not run:
No mains voltage.
• Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
• Use only extension cables with
sufficient lead cross section (see
"Technical Specifications").
Motor overheated, motor protection
relay tripped.
• Remove cause for overheating
(liquid pumped too hot? Pump
blocked by foreign objects?)
• After cooling off the pump will
switch ON again.
Float switch does not switch the
pump ON.
• Ensure there is a sufficient water
supply.
• Make sure the float switch can
move unrestricted.
Motor hums but does not start:
Pump blocked by foreign object.
• Clean pump.
Pump does not pump properly:
Delivery head too high.
• Observe max. delivery head (see
"Technical Specifications").
Discharge hose kinked.
• Straighten discharge hose.
Discharge hose leaky.
• Seal discharge hose, tighten
screw fittings.
Pump runs very noisy:
Pump primes air.
• Ensure there is a sufficient water
supply.
the
casing.
• Adjust float switch correctly.
• Hold pump at an angle when sub-
merging.
soiling
with
Pump runs continuously:
Float switch does not reach lower
position.
• Make sure the float switch can
move unrestricted.
• Set to Manual mode, unplug.
9. Repairs
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
10. Environmental Protection
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on paper
produced with elemental chlorine free
bleaching process.
11. Available Accessories
For this equipment the following acces-
sories are available at specialist dealers.
3
Note:
Illustrations and stock numbers
ENGLISH
can be found at the end of these instruc-
tions.
A
Adaptor C-connector
1 1/2" female,
pipe nipple 1 1/2" x 300 mm
11