Descargar Imprimir esta página

Fault-Finding Chart - SFA SANIPACK Manual De Instalación

Ocultar thumbs Ver también para SANIPACK:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
Warning: Ensure the electricity is turned OFF at the main
switch board before wiring to connector.
All work on cable and motor should only be carried out by a
qualified Saniflo servicing agent, as special tools are required.
The wires in the mains lead of the SANIPACK
DE
are coloured as follows:
®
Brown
Blue
Green/Yellow
8
STANDARDS
This appliance conforms to the European directives and
standards on electrical safety, electromagnetic compatibility
and building products. It conforms to EN 12050-3 (lifting
plant for wastewater containing faecal matter for limited
applications).
9
COMMISSIONING THE UNIT
Once all electrical and plumbing connections have been
checked, flush the WC.
The motor of the SANIPACK
from 10 to 20 seconds, depending on the height and length
of the discharge pipework. If it runs for more than 25 seconds,
check that the discharge pipe is not kinked or blocked.
To check that all connections are watertight, run the
WC, shower, washbasin, one after the other for a few minutes
to represent normal usage. Ensure there are no leaks.
Do not secure the access panel until all the
connections have been checked.
WARNING:
There should be no dripping of water from the
WC cistern or taps. If there is, this will cause the unit to
activate repeatedly as it pumps the water away.
1 0
USAGE
A WC fitted with a SANIPACK
re any special maintenance. The SANIPACK
will operate automatically as soon as the required level of
water enters the case.
The SANIPACK
®
/SANINSIDE
from a domestic WC, washbasin and shower.
IT IS NOT SUITAbLE FOR HEAVY
COMMERCIAL/INDUSTRIAL APPLICATIONS.
WARNING:
If the SANIPACK
hot/boiling water for a prolonged time, the thermal cut out
device will stop the motor from operating. In this case, it will
take approximately one hour for the motor and water to cool
down, after which it will automatically re-activate.
Do not use SANIPACK
discharging at more than 15 litres per minute.
If away for a prolonged time eg. holiday, we would
recommend that you turn off the water supply to the
WC connected to the unit.
WARNING:
The SANIPACK
used for the evacuation of normal human waste, toilet
paper and household WC cleansers.
Damage may occur to the machine if the following are
disposed of in the WC: Cotton wool, tampons, sanitary
towels, condoms, wet wipes, kitchen towels as well as
other fabric or hard items.
A build-up of hair can cause problems, so a hair trap
should be fitted to a shower.
Finally, solvents, acids and other chemicals can also
damage the unit, and will invalidate the warranty.
This device is not designed for persons (including
children) with limited physical, sensory or mental
abilities, or those with minimal experience and
knowledge, unless they are monitored and are given
the necessary instructions for using the device, with
the help of a person responsible for their safety.
Monitor children and make sure they do not play with
the device.
1 1
CARE OF YOUR SANIPACK
• Normal household bleaches/WV cleansers can be used
with a SANIPACK
/SANINSIDE
®
• To avoid the build up of limescale in the unit, use the
following procedure:
• Disconnect the power supply to the unit.
®
/SANINSI-
=
Live
=
Neutral
=
Earth
/SANINSIDE
should operate
®
®
/SANINSIDE
does not requi-
®
®
®
/SANINSIDE
®
will pump away the waste
/SANINSIDE
runs with very
®
®
®
/SANINSIDE
®
with a shower
/SANINSIDE
should only be
®
®
®
/SANINSIDE
.
®
• For 3 to 4 litres of water mixed with a strong
solution of descalent/spirit of salts into the WC pan.
• Leave it to stand for 1 or 2 hours, then reconnect the
electric supply.
• Flush several times to clear.
The frequency of this operation will depend on the
hardness of the water in your locality. We would
recommend this be done about twice a year.
1 2

FAULT-FINDING CHART

For the most part, any inconsistencies in the
operation of the unit will be minor and easily rectified. Please
refer to the chart below. If the problem cannot easily be
remedied in this way, please call our Service Organisation.
Warning - Always disconnect the electricity supply before attempting any
SYMPTOM
• The unit stops.
• The motor intermittently
activates.
• The water in the WC pan
goes down very slowly.
• The motor operates
normally, but continues
to run for a long time.
• The motor does not
activate.
®
• The motor emits a rattling
or crunching sound.
• The motor hums, but
does not turn.
• Cloudy water comes up
into the shower basin
(units with side inlets).
1 3
REMOVING THE SANIPACK
THE WC SUITE
Any replacement of the power supply cable should only be carried
out by an authorised SANIFLO service engineer.
Disconnect the electrical power
A
supply.
Turn off the water feed to the WC cistern. Bail out as much
B
water as possible from the cistern.
Disconnect the discharge pipe.
C
Disconnect the inlet connections.
D
Unscrew the 2 fastering screws (on the ground).
E
Ease the flexible connector off the WC pan spigot and slide the
F
Sanipack out from behind the panel.
Note:
To ease replacement of the lid onto the
SANINSIDE
before replacing.
Do not reconnect the electrical supply until
the re-installation of the unit is complete.
®
1 4
GUARANTEE
SANIPACK
®
to the unit being installed and used in accordance with these
instructions.
work on the SANIFLO
PROBABLE CAUSES
• An object is blocking the
blades.
• The unit has been
running for too long.
• The WC cistern or taps are
running/leaking.
• The external non-return
valve is faulty.
• The inner grille (4) is
clogged.
• The air inlet is clogged
up.
• The length or height of
the installation is over
specification, or there are
too many bends/elbows.
• The pump itself is
blocked.
• The electrical supply is
switched off.
• The electrical supply is
faulty.
• The motor is defective.
• A foreign object has
entered into the grille via
the WC pan.
• The capacitor or motor is
defective.
• Shower installed too low
as compared with the
macerator unit
• Hinged side inlet discs
clogged up
/SANINSIDE
®
®
case, lubricate the rubber seal with liquid soap
/SANINSIDE
carries a 2-year guarantee subject
®
®
REMEDIES
• Ask an approved repair
agent to intervene.
• Check the installation
upstream.
• Clean or replace the
non-return valve.
• Call a service engineer to
clear the grille.
• Clear the air inlet.
• Check the installation.
• Call a service engineer to
unblock the unit.
• Restore the electrical
supply.
• Call a service engineer to
inspect the motor.
• Call a service engineer to
inspect the motor.
• Call a service engineer to
remove the foreign object
from the unit.
• Call a service engineer to
inspect the motor.
• Check the installation
• Call a service engineer to
remove the foreign
object.
FROM
®
SANIPACK
®
/

Publicidad

loading

Este manual también es adecuado para:

Saninside