1.2
data sheet
M AGTROL
LMU Series
Load Monitoring Units
Features
•
For use with full-bridge strain gauge transducers
(sensitivity 0.5 to 4 mV/V)
•
Voltage input for load summation or for individual use
(without sensor)
•
2 to 4 level detectors with relay output contacts
•
0–20 mA or 4–20 mA DC current output
•
±10 V voltage output(s)
•
Provides continuous detection of signal line failure and
short circuits («OK» signals)
•
Includes integrated test equipment (B.I.T.E.) with
continuous power supply monitoring
•
Compatible to CE Standards
•
IP 65 aluminum housing
Features of LMU 216 only:
•
4 level detectors with output contacts, 2 of them with
programmable memory
•
Summer with 4 inputs
•
Tare function
•
Optional balancing and comparator sub-module
Description
The Magtrol Load Monitoring Unit is specially designed for
strain gauge transducer applications. Specifically developed
for use with Magtrol load measuring pins and load-force-
weight sensors, the LMU Series provides excitation current
and amplifies the output signal of full-bridge strain gauges.
Load Monitoring Units are flexible and fully configurable
due to DIP-switches and jumpers which allow the unit to
be easily installed—no solder connections are required. The
level detectors and the outputs can be dedicated either to the
MoDel coMparison
Description
Voltage Output
Current Output
Relays
Summation
1
LMU 212
1 transducer input
1 × 0–10 V
1 × 0–20 mA or 4–20 mA
2
2 signals
LMU 217
LMU 216
full-bridge input, to the voltage input, or to the sum of both
(see "Application Selection" at the top of page 3). A built-in
auto-diagnostic system detects any short circuits or signal line
failures, thus allowing the system to be used in applications
where safety is important. If a problem is detected, both
relays are deactivated and the output voltage (respective
current) changes to >10 VDC and >20 mA.
The LMU is fully compatible with European Community (CE)
standards. Its IP 65 aluminum housing allows the system to
be used in harsh environments. Using SMD (surface mounted
device) technology, the LMU allows the maximum performance/
price ratio for strain gauge transducer monitoring.
LMU 217
2 transducer inputs (2 × LMU 212)
2 × 0–10 V
2 × 0–20 mA or 4–20 mA
4
3 signals
2
Magtrol Monitores de Carga LMU 212 y 217
LMU
Data Sheet
LMU 212
LMU 216
1 transducer input
3 × 0–10 V
1 × 0–20 mA or 4–20 mA
4
4 signals
www.magtrol.com