The programming is done using a button and 2 LED's, mounted as shown
on figure(*).
Red LED:
During normal functioning it has 3 indications:
l
- LED OFF: Indicates it is not generating Advance
- LED ON: Indicates it is generating Advance.
- LED blinking: There is a detection MISTAKE of the CKP and
CMP entries. Does not generate Advance. This condition can
be solved executing a Self-programming.
During the programming stage it shows the option we are modifying, which
is done through the amount of blinks.
Green LED:
Shows the value of the option selected through the blinks.
l
Button:
Allows to select the different programming options and the
l
different values within each option.
(*)Programming can also be done through a PTAa 105 terminal or a
dedicated program on PC.
Programming way:
With the vehicle in contact, press the button and
l
release it, you will see the LED´s start blinking, in this case the red LED will
blink indicating it is in the option 1 (Advance Curve), the green LED will
blink indicating in which curve the TAP is set up. If no change is made
through the button, the LED's will repeat the previous sequence 5 times
and go back to normal running.
Selection of options:
to pass from one option to the other, the button
l
must be kept pressed until the red LED stays ON and then release it. For
instance, if it is in option 1 (red LED 1blink), keep the button pressed until
de red LED lights, release the button, now the device will be in option 2
(the red LED will blink twice). If the procedure is repeated, the option 3 will
take place and so on until getting to the last option, where, if the procedure
is repeated, the option 1 will be reached.
10. Instructions Manual
Change of values: to modify the value of an option, enter in programming
l
mode and select the option with the previous procedure. Once it is in the
wanted option, each time the button is pushed shortly, the value is modified
passing to the following one, until getting to the last one, where if pushed
shortly again, it passes to the first one.
Advance curve
12°
15°
Activation Point
TPS Advance
0-5 V
TPS type
5-0 V
OC
CKP
5V
Outlet signal
12V
OC
CMP
Outlet signal
5V
12V
ON
CMP
Activation
OFF
OK
Slf - programming
Error
11. Instructions Manual
Red LED
Green LED
flares