Thank you for purchasing Lumax
Pump. Please read this Operational Manual carefully. It is important that you read the entire manual to become
®
familiar with the unit before you begin assembly and/or operate the unit. Please store this Operational Manual in a safe place for later reference.
CAUTION: This pump is designed for use with Chemicals of Light to Medium Viscosity. Always Pump in a well ventilated area.
and Extremely Dangerous to pump. Ground Wires are essentially required for Gasoline and Flammables.
this Manual. Refer to the materials below, to check which Fluids can be pumped, using this Pump.
WETTED MATERIALS: LX-1326: Polypropylene (PP); Stainless Steel (SS 201); Viton
LX-1327: Polypropylene (PP); Polypropylene; Glass Fiber Reinforced (PPR); Stainless Steel (SS 304); Viton
Materials (Can be Pumped) - LX-1326 and LX-1327: Acetic Acid 20-50%; Alcohols - Amyl, Benzyl, Butyl, Ethyl (Ethanol), Hexyl (1-Hexanol); Isobutyl; Isopropyl; Propyl; Ammonium Hydroxide, Anti Freeze
(Alcohol & Glycol Base); Boric Acid - 30%; Calcium Carbonate; Calcium Chloride; Calcium Hypochlorite - 20%; Calcium Sulfate; Citric Acid; Copper Sulfate; Detergent Solutions; Diesel Oil (Fuel ASTM #2);
Ethylene Glycol; Formaldehyde; Formic Acid; Fruit Juices; Fuel Oils (ASTM #1-#9); Gasoline (Unleaded & Petrol); Glycerol (Glycerine); Heptane (Brake Cleaner); Hexane; Hexyl Alcohol (Hexanol); Hexylene
Glycol (Brake Fluid); Hydrogen Peroxide - 30%; Isobutyl Alcohol; Isopropyl Alcohol; Lactic Acid; Lubricating Oils (Petroleum); Mineral Oil (Petroleum); Motor Oil; Nitric Acid - 50%; Oils: Animal, Mineral
and Vegetable; Oxalic Acid; Petroleum (Crude Oil); Phosphoric Acid - 50%; Photographic Developer; Potassium Chloride; Potassium Hydroxide (Caustic Potash); Propylene Glycol; Salt Water (Brine); Sea
Water (Brine); Silicone Oils; Soap Solutions; Soda Ash (Sodium Carbonate); Sodium Bicarbonate; Sodium Chlorate; Sodium Chloride; Sodium Chromate; Sodium Hydroxide - 50%; Sodium Nitrate; Sodium
Nitrite; Sodium Peroxide; Sodium Phosphate; Sodium Silicates; Sodium Sulfate; Sodium Sulfide; Sodium Sulfite; Stearic Acid; Stoddard Solvent; Sulfuric Acid - 75%; Tallow; Transformer Oil ; Transmission
Fluid (Type A); Urea/DEF/Ad Blue; Varnish; Vegetable Juices; Vinegar; Water: Fresh and Distilled (Deionized); Wines; Zinc Chloride and Zinc Sulfate
Materials (Should Not be Pumped) - LX-1326 and LX-1327: Actaldehyde; Acetic Anhydride; Acetone; Alcohols: Diacetone and Methyl (Methanol); Aluminum Sulfate; Ammonia, Anhydrous; Ammonia,
Liquid; Benzene; Benzoic Acid; Bleach Solutions; Brake Fluid (Hexylene Glycol); Chlorine, Wet; Chlorox; Copper Chloride; Ethyl Acetate; Hydraulic Oil; Hydrochloric Acid: 20%; 30%; Jet Fuels (JP1 to JP6);
Kerosene; Lacquers; Lacquer Solvents; Methyl Ethyl Ketone; Naphtha; Sodium Hypochlorite; Toluene, Toluol; Trichlorethane; Trichlorethylene; Turpentine; Vegetable Oils and Xylene
WETTED MATERIALS: LX-1328: Ryton
®
Materials (Can be Pumped) - LX-1328: All fluids as for LX-1326 & LX-1327 and additionally; Aluminum Sulfate; Benzene; Benzoic Acid; Chlorox; Jet Fuels (JP1 to JP6); Kerosene; Methyl Ethyl Ketone;
Naphtha; Toluene; Toluol; Trichlorethane; Trichlorethylene; Turpentine; Vegetable Oils and Xylene
Materials (Should Not be Pumped) - LX-1328: Actaldehyde; Acetic Anhydride; Acetone; Alcohols: Diacetone and Methyl (Methanol); Ammonia, Anhydrous; Ammonia, Liquid; Bleach Solutions; Brake
Fluid (Hexylene Glycol); Chlorine, Wet; Copper Chloride; Ethyl Acetate; Hydraulic Oil; Hydrochloric Acid: 20%-30%; Lacquers; Lacquer Solvents and Sodium Hypochlorite.
CAUTION: The above Materials List is to be referred for guidance only
application before permanent installation. Ratings of chemical behavior listed in this manual apply at a 48 hour exposure period. Lumax has no knowledge of possible effects beyond this period. All
recommendations are based on room temperature (72°F/22°C) exposure. Compatibility results may deviate from these recommendations at elevated temperatures. Recommendations are based on
presence of listed chemical only. Mixtures containing more than one chemical can greatly affect chemical compatibility. Polypropylene products and components should not be used with low flash
point chemicals, regardless of chemical compatibility results. Failure, improper selection, or improper use of the products referred to and described herein or related items can cause severe personal
injury or property damage. This document and other information provides product options for further investigation by users having technical expertise. It is important that you analyze all aspects of
your application and review the information concerning the product or system.
Due to the variety of operating conditions and applications for these products, the user, through his or her own analysis and testing, is solely responsible for making the final selection of the products
and assuring that all performance, safety and warning requirements are met. The materials described and referred to herein are subject to change at any time without notice. Lumax does not warrant
(neither express nor implied) that the information in this chart is accurate or complete or that any material is suitable for any purpose. If there is any question about
pumped,
do not operate the pump.
Check
WARNING
SAFETY FIRST! - FOR YOUR OWN PROTECTION READ, UNDERSTAND AND OBSERVE THESE SAFETY TIPS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT!
Pumps should only be used as recommended. Any tool can fail if it is misused. To avoid Serious Personal Injury when using your Pump, follow these Safety Tips and Rules :
Do Not use Pump for the purpose it is not intended for.
Do Not Force use Pump. It will do the job Better and Safer at the Rate for which it was Intended. Never Use Handle Extensions to Increase Leverage.
Always Wear Appropriate Protective Clothing and Equipment. Do Not wear Loose Clothing or Jewelry. They can be caught in Moving Parts.
Protective Gloves and Non-skid Footwear are recommended when working with Pumps. Approved Guards and Protective Equipment, such as,
Impact Resistant Safety Glasses, Safety or Chemical Splash Goggles, Full Face Shield, Safety Shoes, Arm Guards, Protective Gloves and Apron Must
be used for Operator Protection. Wear Protective Hair Covering to contain Long Hair.
Use Respirator. Always wear proper Face Mask to avoid Inhalation of Fumes and Hazardous Gases. Never Smoke near any fluids that are to be
pumped. Always Pump in a well ventilated area.
Stay Alert. Watch what you are doing. Use Common Sense. Do Not operate Pump when you are Tired or under the influence of any medications.
Be Alert at All Times especially during Repetitive, Monotonous Operations. You may have demonstrated a certain product hundreds of times, but
do not be lulled into Complacency due to a False Sense of Security. Tools can be extremely unforgiving if not used carefully and as per instructions.
Do not Over-reach. Keep Proper Footing and Balance at all times.
Keep Visitors Away. All Visitors should be kept away from Work Area. Do Not let Visitors operate Pump.
Check Damaged Parts. Before use of the Pump, carefully check for any Damaged Parts to determine that the Pump will operate Properly and
Perform its intended function. Check for Alignment of Moving Parts, Binding of Moving Parts, Breakage of Parts, Mounting, and any other Conditions
that may affect its Operation. Any Part that is damaged should be properly Repaired or Replaced by an Authorized Service Center.
Maintain Pumps with Care. Keep Pumps Clean and regularly serviced or maintained for Better and Safe Performance. Follow Instructions for
Lubricating and changing Accessories. Inspect Pumps Periodically and if Pump or any of its parts are Damaged - have it Repaired by an Authorized
Service Facility. Always keep your Pumps Inspected and Replace Immediately, if damaged or Worn.
Store Idle Pump. When not in use, Pumps should be Stored in Dry, High and/or in Locked-up place. Childproof the Pump and work area.
Pumps Must only be repaired by Qualified Technicians.
• Always check local area Laws and Ordinances regarding Handling, Pumping and Disposing of Liquids. Dispose of pumped fluid properly.
Do Not drain into street drains, house drains, or backyards. Contact your local Municipal Waste Management officials for proper disposal
methods. If there is any question about a condition being safe or unsafe, do not operate the pump.
TECHNICAL SPECIFICATIONS:
• Equipped with Two-tier Threaded Bung 1-1/2" (40mm) and 2" (50mm).
Fits 15-55 Gallon (57-210L) Drums with Standard 1-1/2" and 2" Bung Opening
• 39" (1m) Suction Tube for 15-55 Gallon (57-210L) Drums. 1-1/4" (32mm) Inlet Port and 3/4" (19mm) Spout
• Delivers 16 oz. (500mL) per Stroke
• Removable Spout is threaded to fit all garden hoses
• Includes Non-drip Spout
For Warranty information, please visit: www.Lumax.com
PLASTIC HAND LEVER-ACTION CHEMICAL & FUEL PUMP
For use with 15-55 Gallon (57-210 l) Drums
Polyphenylene Sulfide (PPS); Stainless Steel (SS 316); Teflon
in selecting equipment for appropriate chemical
with Lumax as to whether it is safe or unsafe, to operate the pump.
(Fluoropolymer Elastomer)
®
(PTFE); Viton
(Fluoropolymer Elastomer)
®
®
© 2016 Lumax. All Rights Reserved. Lumax ® and the
Products described in it are Copyrighted by Lumax ® , with
All Rights Reserved. This Form may not be Copied in Whole
or Part, without the Express Written Consent of Lumax ® .
Viton ® ; Ryton ® and Teflon ® are registered trademarks
of their respective companies
WARNING: Although Gasoline is Oil based, it is Explosive
Never Smoke near any fluids that are to be pumped. Follow the Safety Tips in
(Fluoropolymer Elastomer)
®
ALWAYS test your equipment under the specific conditions of your
compatibility.
any Material that can or cannot be
Form:
LX-1326-28-IS

Publicidad

loading

Resumen de contenidos para Lumax LX-1326

  • Página 1 ® Materials (Can be Pumped) - LX-1328: All fluids as for LX-1326 & LX-1327 and additionally; Aluminum Sulfate; Benzene; Benzoic Acid; Chlorox; Jet Fuels (JP1 to JP6); Kerosene; Methyl Ethyl Ketone; Naphtha; Toluene; Toluol; Trichlorethane; Trichlorethylene; Turpentine; Vegetable Oils and Xylene Materials (Should Not be Pumped) - LX-1328: Actaldehyde;...
  • Página 2 (Elastómero de Fluoropolímero) Materiales (pueden ser bombeados) - LX-1328: Todos los fluidos para LX-1326 & LX-1327 y adicionalmente: El sulfato de Aluminio; Benceno; Ácido Benzoico; Clorox; Los Combustibles de Aviación (JP1 para JP6); Kerosén; Metiletilcetona; Nafta; Toluano; Tricloroetano; Tricloroetileno; Trementina; Aceites Vegetales y Xileno Materiales (no deberían ser bombeados) - LX-1328: Acetaldehído;...
  • Página 3 En raison de la variété des conditions d'opération et applications pour ces produits, l’utilisateur, à travers ses propres analyses et essais, est le seul responsable de faire la sélection finale des produits et garantir que tous les conditions de performance, sécurité et précaution soient remplies. Les matériaux décrits et référencés dans ce document peuvent être modifiés sans préavis. Lumax ne garantit pas (ni exprime, ni laisse entendre) que les informations sur ce tableau sont précises ou complètes, ou que n’importe lequel matériel est approprié...
  • Página 4 Complete Range of High Quality Barrel and Bucket Pumps, available from Lumax ® La gama completa de las bombas del de la alta calidad está disponible de Lumax ® La gamme complète des pompes de haute qualité sont fournie par Lumax ®...

Este manual también es adecuado para:

Lx-1327Lx-1328