Installer setup
Setup function
5 Heating cycle rate
(CPH: cycles/hour)
TH2110DH, TH1110E1,
TH1110DH and
TH1100DH
6 Auxiliary heat
cycle rate (CPH)
TH2210DH and
TH1210DH
9 Compressor
cycle rate (CPH)
13 Early Start (TH2110DH
and TH2210DH)
14 Temperature
display
15 Compressor
protection
20 Clock display
(TH2110DH and
TH2210DH)
25 Lower temperature
range (TH1100DH only)
40 Restore program
schedule to default
(TH2110DH and
TH2210DH)
CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage,
avoid cycling the compressor quickly.
PRO TH2000DH/TH1000E1/TH1000DH Series
Settings & options (factory default in bold)
5
For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficien-
cy
6
For electric furnaces
[Other cycle rate options: 2 or 4 CPH]
5
For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
6
For electric furnaces
[Other cycle rate options: 2 or 4 CPH]
3
Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5, or 6 CPH]
1
On **See page 8
0
Off
0
Fahrenheit
1
Celsius
1
Five-minute compressor off time (See page 8)
0
No compressor off time
0
12-hour display
1
24-hour display
0
Standard range 40°F to 90°F (4.5°C to 32°C)
1
Lower range (for garage mode) 35°F to 90°F
(1.5°C to 32°C)
0
Off
1
On - program schedule default settings are listed in the
operating manual
7
69-2609EFS—13