Power Options; Terminal Designations - Honeywell Home PRO TH2000DH Serie Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Power options

KEEP WIRES IN
THIS SHADED AREA
TH2110DH TERMINAL
BLOCK SHOWN
CONNECT C FOR PRIMARY
AC POWER (OPTIONAL IF
BATTERIES ARE INSTALLED)
Wiring

Terminal designations

TH2110DH/TH1110E1/
TH1110DH:
B
Changeover valve energized in
heating
O
Changeover valve energized in
cooling
G
Fan relay
Y
Compressor contactor
W
Heat relay
C
24 Vac common. For 2-transformer
systems, use common wire from
cooling transformer.
R
24 Vac power from heating
transformer
Rc
24 Vac power from cooling
transformer
TH2110DH/TH1110E1/
TH1110DH:
O
G
Y
W
C
TH1100DH:
W
Heat relay
C
24 Vac common
R
24 Vac power
REMOVE FACOTRY-
INSTALLED JUMPER
ONLY FOR TWO-
TRANSFORMER
SYSTEMS
W C
M32806
R
Rc
M32808
TH1100DH
W C
R
Not
Used
M32810
PRO TH2000DH/TH1000E1/TH1000DH Series
INSERT BATTERIES FOR
PRIMARY OR BACKUP POWER
TH2210DH/TH1210DH:
B
Changeover valve energized in
heating
O
Changeover valve energized in
cooling
G
Fan relay
Y
Compressor contactor
Aux/E Auxiliary heat relay
C
24 Vac common
R
24 Vac power
TH2210DH/TH1210DH
B
O
G
Y
3
XXXX
Not
Aux/
C
R
Used
E
M32809
69-2609EFS—13
M32807

Publicidad

Tabla de contenido
loading