Standard Self-levelling Laser Level can be used in civil construction, decoration, plumbing,... including the following functions:
- Use this Auto-setting level directly without any adjustment.
- Make the laser horizontal-line/vertical-line to check/correct the horizontal/vertical status of measured objects. Oblique incidence
made by laser vertical-line can also irradiate to walls and roofs.
- This laser level can be used alone, with the base or with the tripod (both included).
- Hang this level on the any height with the ring at the top of the level.
Battery voltage
Operating time
Laser wavelength
Luminous power
Radiation class
Self-levelling range
The horizontal/vertical accuracy
Operating ambient temperature
Storage temperature
- Open the battery-box cover.
- Put two batteries into the box with anode outward.
- Close the box-cover and put down the Power button.
- If don't use the instrument over 3 months, please take the battery out and keep them in cool and dry place
- If the battery leaked, please clean the liquid with soft cloth and avoid contacting with skin
- In order to protect the environment please put the batteries into recycle-bin, forbidding rejecting and burning them.
1. Dial
2. Horizontal-line output
3. Vertical -line output
4. Stationary rings
5. Vial
6. Rubber gasket
7. Power-button
8. Levelling-screw
-4-

TECHNICAL DATA

2x1.5V AA DC
4h cont.
650nm
≤ 1mW
II
± 3º (There will be the glitter-alarm if exceed this range)
0.5mm/m
0ºC – 40ºC
-5ºC ~ 50ºC
BATTERY ASSEMBLING
WARNING
PARTS OF LEVEL

Publicidad