TROUBLE! MATERIAL RUNS OR DRIPS.
WHAT'S WRONG?
Spraying too much material.
Spraying too slowly.
Spraying too close.
Viscosity too thin.
TROUBLE! TOO MUCH OVER SPRAy.
WHAT'S WRONG?
Sprayer too far from surface.
Too much material being sprayed.
TROUBLE! LITTLE OR NO MATERIAL BEING RELEASED.
WHAT'S WRONG?
Spray nozzle/tip clogged.
Pickup tube loose or clogged.
Flow control knob setting too low.
Material too thick.
TROUBLE! MATERIAL BEING SPRAyED IS SPLATTERING.
WHAT'S WRONG?
Viscosity of material is too low.
TROUBLE! SPRAyER PULSATES.
WHAT'S WRONG?
Material in canister almost empty.
TROUBLE! LIqUID COMES OUT SIDE OF CANISTER.
WHAT'S WRONG?
Lid not on square or tight enough.
Paint on threads of canister and lid.
TROUBLE! MOTOR OPERATES PROPERLy BUT DOES NOT SPRAy
WHAT'S WRONG?
Plugged or worn atomizer valve
Atomizer valve missing.
Material too thick.
Plugged spray tip.
Intake filter plugged.
Control knob needs adjusting
Worn piston.
TROUBLE! CANNOT REASSEMBLE UNIT
WHAT'S WRONG?
Skipped an assembly step
TROUBLESHOOTING
WHAT TO DO...
Reduce air flow by turning material adjustment knob.
Increase speed of application.
Increase distance from surface.
Check dilution recommendation.
WHAT TO DO...
Reduce distance to surface.
Reduce flow by turning flow control knob clockwise.
WHAT TO DO...
Clean nozzles.
Check tube.
Increase flow control setting
Check viscosity recommendation
WHAT TO DO...
Thin material per manufacturer recommendation.
WHAT TO DO...
Refill canister.
WHAT TO DO...
Remove lid and reattach squarely and evenly, then tighten lid securely.
Clean threads on top and sides of canister and lid.
WHAT TO DO...
Clean or replace as needed.
Put in atomizer valve.
Thin material.
Clean tip.
Clean intake filter.
Adjust knob.
Clean and oil or replace
WHAT TO DO...
Insert spring and piston into the housing prior to
reassembling.
Press and hold the release button while reassembling
ENGLISH • 31