(*) If "D" type devices are installed (as de ned by EN12453), connect in unveri ed mode, foresee mandatory maintenance at least every six months.
TABLE "A" PARAMETERS
Any modi cation of parameters/logics must be con rmed by pressing S2 > 5s
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf force [%]
Slow-down
distance [%]
T3
Maximum speed
[%]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(***) If the calculated value is less than 30 cm, it is set to 30 cm.
INSTALLATION MANUAL
De nition
LINE
Single-phase power supply
NEUTRAL
TRANSF PRIM
Transformer primary winding connection
Board power supply:
TRANSF SEC
24V~ Transformer secondary winding
MOT +
Connection motor 1
MOT -
AUX 0 -BLINKER
Contact stays closed while leaf is operating.
24V (N.O.) (MAX. 1A)
+REF SWE
Limit switch common
SWC
Closing limit switch SWC (N.C.)
SWO
Opening limit switch SWO (N.C.)
24V~ (-)
Accessories power supply output.
24V~ (+)
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
24 Vsafe
Output active only during operating cycle.
Common
START and OPEN inputs common
START command button (N.O.).
START
Operation according to "3/4-STEP" logic
START command button (N.O.).
START
Operation according to "Residential / apartment building operation" logic
OPEN command button (N.O.).
OPEN
Gate opened with this command. If the input stays closed, the leaves stay open until the contact is opened.
When the contact is open, the automated device closes following the TCA time, where activated.
Common
STOP, PHOT and BAR inputs common
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
PHOTOCELL input (N.C.).
PHOT (*)
Operation according to "PHOTOCELL/PHOTOCELL DURING CLOSING" logic. If not used, leave jumper inserted.
FAULT 1
Test input for safety devices connected to PHOT.
BAR safety edge input (N.C.).
Con gurable according to the "BAR/ 8K2" logic.
BAR (*)
The command reverses movement for 2 sec.
If not used, leave jumper inserted.
Safety edge input (N.C.).
If not used, leave jumper inserted
BAR/8K2
dip
OFF
BAR /
OFF
BAR CL /
BAR TEST /
OFF
BAR CL TEST /
BAR 8K2 /
OFF
BAR CL 8K2
(*)
ON
ON
ON
ON
FAULT 2
Test input for safety devices connected to BAR.
Antenna input.
ANTENNA
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies
close to the antenna can interfere with radio reception. If the transmitter's range is limited, move the antenna
SHIELD
to a more suitable position.
+
+
min.
max.
Waiting time before automatic closing.
0
120
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the
autoset cycle (and subsequently updated), before an obstacle alarm is generated.
10
90
WARNING: It a ects impact force directly: make sure that current safety requirements are met
with the set value (*). Install anti-crush safety devices where necessary.
Set the opening and closing slowdown speed as a percentage of total travel.
1(***)
50
This distance is travelled at low speed.
Set also the movement maximum speed while opening and closing.
Note: when this parameter is modi ed, a new Autoset must be performed to con rm it.
99
60
The graph in g. T shows the variation of the two parameters according to the trimmer rotation
Description
Only active on FW < 3.03
Only active on FW ≥ 3.03
Only active on FW < 3.03
Only active on FW ≥ 3.03
Safety
Safety edge
edge
operation
check dip
dip
NC input, no veri cation, reversal while opening and closing (BAR)
OFF
OFF
OFF
ON
NC input, no veri cation, reversal only when closing, stop when
opening (BAR CL)
ON
OFF
NC input, with veri cation, reversal while opening and closing
(BAR TEST)
ON
ON
NC input, with veri cation, reversal only when closing, stop when
opening (BAR CL TEST)
OFF
OFF
8K2 input, reversal when opening and closing (BAR 8K2)
8K2 input, reversal only when closing, stop when opening (BAR
OFF
ON
CL 8K2)
ON
OFF
---
ON
ON
---
Description
25
ARES BT A 1000-1500 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ares bt a 1500

Tabla de contenido