3. INSTALLATION

3.1 I
C
NSPECT THE
ONTENTS OF THE
Inspect the exterior of the unit for shipping damage. Ensure that there is no damage to the door, door latches, power cord, etc.
Remove and discard the 2 transport brackets (A) and open the door. Discard the styrofoam
fillers (ERV units only) and remove the hardware kit from the unit. Inspect the interior of the
unit for damage. Ensure that heat or energy recovery core, core filters, insulation, dampers, etc.
are all intact.
3.2 L
U
OCATING THE
NIT
C
HOOSE AN APPROPRIATE LOCATION FOR THE UNIT
Within an area of the house where the ambient temperature is between 10°C (50°F) and 65°C (149°F) (basement, furnace
room, closet, etc.).
So as to provide easy access to the interior of the unit, for maintenance.
Close to an exterior wall, so as to limit the length of the insulated flexible duct to and from the unit.
Away from hot chimneys and other fire hazards.
Allow for a power source (standard 3-prong grounding outlet).
For HRV units ONLY: Close to a drain. If no drain is close by, use a pail to collect run-off.
3.3 U
P
NIT
REPARATION
Both HRV and ERV units are equipped with 2 ports having integrated balancing damper. Turn the thumb
screw (A) clockwise to manually open and adjust the damper (B).
HRV units: Set the Fresh air to building port to wide open position, and adjust the Exhaust air to outside
port to 3rd notch.
NOTE: If the unit needs to be balanced, adjust the damper of the Exhaust air to outside port to wide open
position. See Section 7.
ERV units: Set both Fresh air to building port and Exhaust air to outside port to wide open position.
The door latches location can be changed from sides to front of the unit, according to the installation needs.
To do so, turn the unit upside down. Open the latches and unscrew them from the unit. Install the latches on their new locations.
VO0089
B
OX
.
VD0176
L
ATCHES ON SIDES OF THE UNIT
VO0090
L
ATCHES IN FRONT OF THE UNIT
- 9 -
A
VD0183
A
VJ0032
P
ORT WITH INTEGRATED
BALANCING DAMPER
VO0094
B
- T
OP VIEW

Publicidad