Technical Data - RIB JOLLY BIG Serie Manual De Instrucciones

Ocultar thumbs Ver también para JOLLY BIG Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

G
B
TECHNICAL DATA / INSTALLATION JOLLY BIG

TECHNICAL DATA

Electric motors
Max shutter weight
Max shutter surface
Limit switch winding capacity
Nominal functioning torque
Max operating torque
Max lifting force
Max operating force
Pulley revolutions
Pulley diameter
Shaft diameter
EEC Power supply
1 Motor capacity with load
1 Motor Power absorbed with load
Capacitor
Functioning cycles
Daily cycles suggested
Service
Nominal functioning time
Motor weight
Working Temperature
Protection grade
R
OLLING GATE CONTROL
The European Standard EN 12604 "Industrial, Commercial and Garage Doors and
Gates - Mechanical Aspects - Requirements", at the point 4.3. "Protection against
unintentional and uncontrolled movements" requires also that*:
a - The vertically operating door leaves shall be balanced so that the door
leaf can stop in any position, or that the out-of-balance state shall not
produce, in any case, a static force at the primary closing edge of the
door exceeding 150N (15,3 kg / 33,70 lbs). Verify it after having manually
released JOLLY BIG operator.
b - If a spring fails, the resulting out-of-balance static force occurring at the
primary closing edge of the roller shutter shall not exceed 200N (20,4 kg / 44,94
lbs), even when JOLLY BIG operator is manually released. After this failure,
you must intervene on the door to substitute the broken spring and correct
the balance state. Therefore, we suggest you to fraction the roller shutter
weight with an adequate number of springs (*This is a free interpretation).
WARNING: The EN 12445 standard ´Industrial, commercial and garage doors
and gates - safety in use of power operated doors - test methods´ at point
4.1.2 ´safeguarding against hazard of being lifted´ provides that the rolling
gate shall not be able to lift more than 20 kg/44lbs.
In order to meet this standard, RIB suggests to install the control board with
electric power regulation J-CRX (cod. ABJ7080).
kg/lbs
m
2
N°rotat.
Nm
Nm
kg/lbs
kg/lbs
rpm
mm/in
mm/in
W
A
µF
s
kg/lbs
°C
IP
Measurements in mm/in
22
22
22
22
JOLLY BIG ONE
1
280/617
24
240
180
200/440
160/352
8 (50Hz) - 9,7 (60Hz)
240/9,456 - 280/11,032 with adapter ACJ9059
102/4,012 - 76/2,994 with adapter ACJ9058
570 (50Hz) - 550 (60Hz)
2,7 (50Hz) - 2,6 (60Hz)
20
11/24,2
PARTS TO INSTALL MEETING THE EN 12453 STANDARD
COMMAND TYPE
Skilled persons
(out of a public area*)
with manned operation
A
with visible impulses
C or E
(e.g. sensor)
with not visible impulses
C or E
(e.g. remote control device)
automatic
C and D, or E
* a typical example are those shutters which do not have access to any public way.
A: C ommand button with manned operation (that is, operating as long as activated),
like code ACG2012.
B: Key selector with manned operation, like code ACG1010.
C: Motor force regulation.
D: S afety edges or Sensor able to detect an obstacle and/or other safety devices to
keep thrust force within the limits of EN12453 regulation - Appendix A.
E: P hotoelectric cells, eg. code ACG8026 (To apply on the whole height of the door
up to max 2,5 m as indicated on EN 12445 point 7.3.2.2).
I
N ORDER TO ENSURE A CORRECT FUNCTION ONLY
RIB'S COMPONENTS MUST BE USED
1 - JOLLY BIG operator
2 - Photoelectric cells (external)
3 - Push-Button
JOLLY BIG TWO
2
450/992
30
7,5
480
340
440/880
290/638
230V ~ 50-60Hz
1140 (50Hz) - 1100 (60Hz)
5,3 (50Hz) - 5,2 (60Hz)
40
5 - 20s/2s
20
30%
240
16,5/36,3
-10 ÷ +55
30
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
B
-
C or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
4 - Key selector
5 - Tuned aerial
6 - Flashing lamp

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jolly big oneJolly big twoJolly one

Tabla de contenido