System Description; Limitations Of Use - 3M Versaflo S Serie Manual De Instrucciones

Ocultar thumbs Ver también para Versaflo S Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
GZXO
USER INSTRUCTIONS
Please read these instructions in conjunction with the 3M™ Versaflo™ S-Series Headtop Reference leaflet where you will find information on:
• Approved combinations of Air Delivery Units (Powered Air Turbos or Regulators)
• Spare parts
• Accessories
UNPACKING
Your 3M™ Versaflo™ S-Series Headtop pack should contain:
a) S-133S Headtop or S-133L Headtop or S-333SG Headtop or S-333LG Headtop or S-433S Headtop or S-433L Headtop or S-533S Headtop or S-533L
Headtop or *S-655 Headtop or *S-657 Headtop or *S-757 Headtop or *S-855E Headtop * Including hood, premium head suspension, airflow adjustment cover,
size reducing comfort pad and peel-off visor cover.
b) User Instructions
c) Reference Leaflet
^ WARNING
• Proper selection, training, use, and appropriate maintenance are essential in order for the product to help protect the wearer from certain airborne contaminants and
physical hazards.
Failure to follow all instructions on the use of these respiratory protection products and/or failure to properly wear the complete product during all periods of exposure
may adversely affect the wearer's health, lead to severe or life threatening illness, injury or permanent disability.
• For suitability and proper use follow local regulations, refer to all information supplied or contact a safety professional/3M representative (Local Contact Details).
^ Particular attention should be given to warning statements where indicated.

SYSTEM DESCRIPTION

The 3M™ Versaflo™ S-Series headtops are designed to be used with an approved Air Delivery Unit (see Reference Leaflet) to provide respiratory protection.
These products meet the requirements of EN12941 (Respiratory protective devices – Powered filtering devices) and EN14594 (Respiratory protective devices –
Continuous flow compressed air line breathing apparatus).
Note: When regulators and compressed air supply tubes that are exclusively marked EN1835 (Respiratory protective devices - Light duty construction compressed air
line breathing apparatus incorporating helmet or hood) are used with S-Series headtops, the system will only meet the requirements of EN1835.
The 3M S-Series headtops are designed to be used with an approved Air Delivery Unit (see Reference Leaflet) to provide respiratory protection. These products meet
the requirements of EN12941 (Respiratory protective devices – Powered filtering devices) and EN14594 (Respiratory protective devices – Continuous flow
compressed air line breathing apparatus). Air is fed via a breathing tube from the belt mounted Air Delivery Unit to the back of the headtop. The air flows over the top
of the wearer's head and down in front of the face. For the premium head suspension products, the air flow direction can be adjusted to direct air down the side of the
head. Headtops within the S-Series range can also offer face, hair or shoulder protection.
APPROVALS
These products meet the requirements of the European Community Directive 89/686/EEC (Personal Protective Equipment Directive) and are thus CE marked.
Certification under Article 10, EC Type-Examination and Article 11, EC quality control, has been issued by BSI Product Services, Kitemark House, Maylands Avenue,
Hemel Hempstead, Hertfordshire, HP2 4SQ, UK (Notified Body number 0086).

LIMITATIONS OF USE

Use this respirator system strictly in accordance with all instructions:
- contained in this booklet,
- accompanying other components of the system.
(e.g. 3M S-Series Reference Leaflet, Air Delivery Unit User Instructions).
Do not use the S-Series headtops in concentrations of contaminant above 500 times the Threshold Limit Value (TLV) when used with 3M™ Versaflo™ TR-302E and
3M™ Jupiter™ Powered Air Turbos.
Do not use the S-Series headtops in concentrations of contaminant above 200 times the Threshold Limit Value (TLV) when used with 3M™ Versaflo™ V-100E, V-200E
, V-500E or 3M™ Flowstream™, 3M™ Vortex or 3M™ Vortemp™ Regulators.
Do not use the S -Series headtops in concentrations of contaminant above 10 times the Workplace Exposure Limit (WEL) when used with 3M™ Dustmaster™
Powered Air Turbo.
Do not use for respiratory protection against unknown atmospheric contaminants or when concentrations of contaminants are unknown or immediately dangerous to
life or health (IDLH).
Do not use in atmospheres containing less than 19.5% oxygen. (3M definition. Individual countries may apply their own limits on oxygen deficiency. Seek advice if in
doubt).
Do not use these products in oxygen or oxygen-enriched atmospheres.
These products do not supply oxygen.
Only use with the Air Delivery Units, spare parts and accessories listed in the Reference Leaflet and within the usage conditions given in the Technical Specification.
Only for use by trained, competent personnel.
Leave the contaminated area immediately if:
a) Any part of the system becomes damaged.
b) Airflow into the headtop decreases or stops.
c) Breathing becomes difficult.
d) Dizziness or other distress occurs.
e) You smell or taste contaminants or irritation occurs.
Never modify or alter this product. Replace parts only with original 3M spare parts.
Do not use oxygen or oxygen-enriched air.
^ Do not use around heat, flames, or sparks.
Select and wear appropriate protection when exposed to sparks and/or flames.
In case of intended use in explosive atmospheres, contact 3M Technical Service.
If using in Supplied Air mode, ensure that:
• The source of the air supply is known.
• The purity of the air supply is known.
• The air supply is of a breathable quality to EN12021.
^ Users should be clean-shaven where the respirator's face seal comes into contact with the face.
(S-100, S-300, S-400 and S-500 series)
Use only with recommended spectacles. Eye protectors against high speed particles worn over standard ophthalmic spectacles may transmit impacts, thus creating a
hazard to the user. Contact your supplier.
High winds above 2m/s, or very high work rates (where the pressure within the headtop can become negative) can reduce protection. Adjust equipment as appropriate
or consider an alternative form of respiratory protective device.
4

Publicidad

Tabla de contenido
loading

Tabla de contenido