Operation - Desa TC106 Manual Del Propietário

Ocultar thumbs Ver también para TC106:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INStALLAtION
Continued
4. Open propane supply valve on propane
tank(s) slowly. Note: If not opened slowly,
excess-flow check valve on propane tank
may stop gas flow. If this happens, you
may hear a click inside the regulator as-
sembly, this is the check valve closing. To
reset the excess flow check valve, close
propane supply valve and open again
slowly.
5. Check all connections for leaks. Apply
mixture of liquid soap and water to gas
joints. Bubbles forming show a leak that
must be corrected.
Propane Supply
Valve
Propane
Tank
Figure 3 - Regulator Position
Hose
Figure 4 - Hose and Valve Inlet
(200,000 Btu Model Shown)
119588-01A
Hose
Regulator
POL
Fitting
Valve Inlet
www.desatech.com

OPERAtION

WARNING: Review and un-
derstand the warnings in the
Safety Information section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.
80,000 bTu HEATER
TO START HEATER
1. Follow all installation, ventilation and
safety information.
2. Locate heater on stable and level surface.
Make sure strong drafts do not blow on
heater.
3. Make sure unit is turned off by slightly
depressing and turning control knob fully
clockwise to OFF.
4. Open propane supply valve on propane
tank(s) slowly. Note: If not opened slowly,
excess-flow check valve on propane tank
may stop gas flow. If this happens, you may
hear a click inside the regulator assembly,
this is the check valve closing. To reset the
excess flow check valve, close propane
supply valve and open again slowly.
5. Slightly depress and turn control knob
counterclockwise to the LO position (see
Figure 5).
6. With the control knob pushed all the way
in, press and release the piezo ignitor
button. Keep pressing piezo ignitor but-
ton until the burner lights. Hold control
knob down for a maximum of 15 seconds
while attempting ignition. If heater does
not ignite, release control knob and wait
3 minutes before attempting to reignite.
7. After ignition, hold control knob down
for about 30 seconds. This activates the
automatic control system.
Piezo Ignitor Button
Figure 5 - Control Knob and Piezo Ignitor
Control Knob
Off/
Apagado/
Arrêt
Lo/Bajo/
Bas
Med/
Medio/
Moyen
Hi/Alto/
Haut
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tc112Tc113Tc114Tc115

Tabla de contenido