3.5KW Generator
Operation (cont'd)
Starting
1 Make sure the electrical powered tools/equipment that will be used are
not plugged into the generator while the engine is started.
2 Turn the 120 volt AC circuit breaker
to its "ON" position.
3 Open the fuel valve (40).
4 Close the choke lever (21A) to about
1/8" clearance.
5 Turn the engine power wwitch (2) to
its "ON" position.
6 Hold the start handle (41A) loosely
and pull it slowly several time to
allow the gasoline to flow into the
Engine's carburetor. Then hold the
start handle firmly and pull the rope
hard and fast. Pull the rope all the
way out, using two hands if
necessary. If necessary pull the rope
several times until the engine starts.
7 Allow the engine to run for several
seconds. Then, open the choke lever
all the way.