Installation (drawing 2)
This device must never be put in the water. Always install outside the bath. Make sure there is always water flowing through the unit when
the lamp is on.
1 Fit the unit with the three-piece couplings (I) in the circuit.
2 Fit the unit with the pipe clips (O) (supplied with the set) at a permanent installation point and tighten the three-piece coupling (I).
3 Fit the lamp (K) in the white lamp holder (L); than slide the lamp (K) carefully into the quartz glass (M) and tighten the screw cap (N)
finger-tight on the unit.
4 Start the pump and check the flow of the system and that it is not leaking. Then check the seals (P) for correct positioning both at the
connections and the quartz glass (see drawing 2).
5 Plug the power lead of the UV-C device into an earthed electrical socket with an earth leakage switch. Check that the lamp lights up; this
can be seen through the transparent attachments on the device.
6 The device is switched off by removing the plug from the electrical socket.
7 Make sure that there is approximately 1 meter clearance in front of the UV-C device for subsequent disassembly operations.
Dismantling/Maintenance
During maintenance/dismantling always disconnect electrical current. The device needs to be cleaned twice a year. If algae or lime scale
forms on the quartz glass tube (M) containing the lamp, it must be cleaned. The special lamp must be replaced after 9,000 hours. Clean the
stainless steel interior with a soft brush.
1 Unscrew the three-part couplings (I) and allow the water to flow out of the device.
2 Twist the cap (N) containing the lamp off the device and replace the special lamp (K) if needed. Please handle with care as these are very
delicate parts.
3 Carefully remove the quartz glass (M) with a large flat screwdriver (see drawing 3). Never force it!
4 Clean the quartz glass with an appropriate solution. Always use a soft cloth to clean the glass to prevent scratches.
5 When replacing the quartz glass in the housing make sure that it is placed on the seals (P) correctly and carefully slide the end of the quartz
glass into the receiving guide (Q) (see drawing 4)
If the housing or the electrical section must be replaced then the earthing should first be disconnected from the housing.
When assembling a new housing or electrical section then please read Installation and Dismantling first. Make sure that you keep the various
bits of the earthing properly. These are not supplied with a new housing or electrical section. If there is any doubt about the connection,
consult a certified electrician.
Technical specifications
Lamp TUV 4P-SE T5
UV-C (W)
UV-C (%) after 9,000 hours
Bath content (L.)
Max. flow through
Max. pressure
Guarantee conditions
The product is guaranteed for 24 months from the day of sale against factory production faults. The lamp, the quartz glass and the starter are
not covered by the guarantee. Complaints relating to guarantees can only be dealt with if the product is returned postage paid and is
accompanied with a valid proof of purchase. Guarantee repairs may only be done by the supplier. We will not honour guarantee claims
resulting from installation or operation mistakes. Defects arising from poor maintenance are also not covered by the guarantee. The supplier
is in no way responsible for damages resulting from wrong use of the product. The supplier is not liable for any consequential damage
resulting from failure of the equipment unit. Complaints due to transport damage can only be accepted if the damage is determined and
confirmed by the shipping agent, railway company or post office upon delivery of the goods.
Only then it will be possible to assert claims against the shipping agent, railway company or post office.
UV-C 15.000
UV-C 40.000
16 Watt
40 Watt
3,9 Watt
15 Watt
75%
85%
15.000L
40.000 L
7.200 l/h
20.000 l/h
3 bar
3 bar
UV-C 75.000
75 Watt
25 Watt
80%
75.000 L
30.000 l/h
3 bar
5