Troubleshooting - Ingersoll Rand PowerForce PF150 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Problem
Low speed or tool will not function
Low speed or tool will not function
Low speed or over speed
Low speed or tool will not function
Low speed or tool will not function
Low speed
Low speed
Free Speed
Model
Model
rpm
rpm
PF150
18000
H Tested in accordance with PNEUROP PN8NTC1.2
z Tested to ISO8662

TROUBLESHOOTING

Possible Cause
Lack of lubrication
Low pressure
Low pressure or high pressure
System leakage
Debris build up in tool
Regulator not fully open
Clogged or dirty Exhaust filter
SPECIFICATIONS
Pad Diameter
H Sound Level
in
mm
Pressure
5
127
86.7
3
Action
Add 1.5 cc of Powerforce oil #50 to
the tool
Ensure system regulators are set
properly to have 90 psi (6.2 bar/
620 kPa) at the tool inlet.
Ensure proper hose size. Long
hose lengths may require a hose
with a 1/2" ID or larger
Ensure connections are tight and
hoses are not damaged
Flush tool with 1.5 cc of Power-
force oil #50
Turn regulator to adjust the tool
speed to maximum speed
Clean out exhaust by unscrewing
muffler. Clean muffler and reinstall.
z Vibrations
dB(A)
Level
Power
m/s
99.7
1.2
Average Air
Consumption
2
cfm
3

Publicidad