3. Technical data
Phoenix Inverter
INVERTER
Cont. AC power at 25 °C (VA)
Cont. power at 25 °C / 40 °C (W)
Peak power (W)
Output AC voltage / frequency
Input voltage range (V DC)
Low battery alarm (V DC)
Low battery shut down (V DC)
Low battery restart (V DC)
Max. efficiency (%)
Zero-load power 12 / 24 / 48 V (W)
Zero-load power in Search Mode (W)
Search Mode shut down / turn on (W)
GENERAL
Protection
(2)
Remote on-off
Operating temperature range
Humidity (non condensing)
Internal DC fuse (type: MIDI fuse) (A)
ENCLOSURE
Material & Colour
Protection category
Battery-connection
Standard AC outlet
Other outlets (at request)
Weight (kg / lbs)
Dimensions (hxwxd in mm)
(hxwxd in inches)
STANDARDS
Safety
Emission / Immunity
1. Non linear load, crest factor 3:1
2. Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
4
12 Volt
12/800
24 Volt
24/800
48 Volt
48/800
(1)
700 / 650
120VAC +/- 5% or 230VAC +/- 3%
91 / 93 / 94
6 / 6 / 6
200 / 100 / 60
230V: IEC-320 (IEC-320 plug included), CEE 7/4 (Schuko)
BS 1363 (United Kingdom)
AN/NZS 3112 (Australia, New Zealand)
6,5 / 14.3
EN55014-1 / EN 55014-2 / EN 61000-6-2 / EN 61000-6-3
800
1600
9,2 - 17,3 / 18,4 - 34,0 / 36,8 - 68,0
10,9 / 21,8 / 43,6
9,3 / 18,6 / 37,2
10,9 / 21,8 / 43,6
2
20 / 30
a - e
Yes
-40 to +50°C (fan assisted cooling)
max 95%
Aluminium
Blue Ral 5012
IP 20
Battery cables of 1.5 meter
120V: Nema 5-15R
104x194x305
4.1x7.7x12
EN 60335-1
12/1200
24/1200
48/1200
1200
1000/ 900
2400
50Hz or 60Hz +/- 0,1%
92 / 94 / 94
8 / 9 / 8
2,3
20 / 30
200 / 150 / 100
8,5 / 18.7