PENTHA
G 2
B
MONITOR
SAFETY PRECAUTIONS
-
Always disconnect the power supply before making modifications to the device.
-
The fitting and handling of these devices must be carried out by
-
The wiring must run at least 40 cm away from any other wiring.
-
Do not overtighten the screws on the connector.
-
Install the monitor in a dry protected location free from the risk of dripping or splashing water.
-
Do not place in humid, dusty or smoky locations, or near sources of heat.
-
Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
-
Always follow the instructions contained in this manual.
( )
CHARACTERISTICS
*
-
Hands-free monitor.
-
7" TFT colour screen.
-
Monitor with simple installation (non-polarised 2 wire BUS).
-
Touch screen for access and selection of menu functions.
-
User menu.
-
Installer menu.
-
Screen, volume and control settings menu.
-
Capacitive menu access and (slave monitor only) start/stop communication button.
-
Monitor status light.
-
'Divert call' mode LED.
-
'Do not disturb' mode LED.
-
DIP switches for setting the monitor address (call code) and end of line.
( )
SYSTEM OPERATION
*
-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that
the call is being made and LED
will turn on. If vocal synthesis is enabled, a 'Call is in progress'
message appears indicating that a call is being made. At this moment, the apartment's monitors
receive the call. If another apartment is called by mistake, press the button for the correct
apartment and the first call will be cancelled.
-
The call lasts for 40 seconds and, when received, the image appears on the master monitor
without the visitor knowing.
House kit application
'apartment 1' or monitor with code 16 if the call is in 'apartment 2') when receiving the call without
the visitor being alerted.
If the call is not answered within 40 seconds, LED
-
To establish communication, press option
the
logo on the front of any slave monitor in the apartment (unless the 'display image in
call' function is enabled on the slave monitor, in which case, option
LED on the door panel will illuminate. If the monitor is a PENTHA GB2/H with icon
front, make sure that the hearing aid is 15 and 25 cm away from the monitor to ensure maximum
audio quality during communication with the door panel.
-
Communication will last for one and a half minutes or until option
pressed. When communication has finished, LEDs
freed. If vocal synthesis is enabled, a 'Communication is finished' message will indicate that the
call is over.
1
2
-
To open door 1 or 2, press option
/
processes: one press will activate the lock release for 5 seconds and LED
for 5 seconds. If vocal synthesis is enabled, a 'Door Opened!' message will be indicated on the
door panel.
( )
For more information, see the "TPENTHA GB2 user manual (code
*
https://doc.golmar.es/search/manual/50121913
authorised personnel
: the image appears on the monitor (with code 0
will turn off and the channel will be freed.
on the screen of the master monitor or
must be pressed), and
on the monitor screen is
and
will turn off and the channel will be
on the monitor screen during the call or communication
will also illuminate
50121913)".
2
PENTHA
DESCRIPTION OF THE MONITOR
( )
*
.
g
f
a.
Microphone.
b.
Monitor status light and capacitive menu access (in
standby) / slave monitor communication start button.
c.
Communication with hearing aids (PENTHA GB2/H).
Sets the hearing aid switch to T-mode.
d.
Speaker.
LED : S
'Divert call' mode LED:
Off: 'Divert call' mode disabled.
On: 'Divert call' mode enabled.
'Do not disturb' mode LED:
Off: 'Do not disturb' mode disabled.
On: 'Do not disturb' mode enabled.
( )
*
Monitor code setup:
1-apartment kit
APARTMENT 1
PENTHA
CODE 0
( )
1
2-apartment kit: Monitor code 16 is the last,
DIP 6 of the end of line to ON.
( )
INSTALLATION OF THE MONITOR
*
on the
Location
1.60m
( )
For more information, see the "TPENTHA GB2 user manual (code 50121913)"
*
https://doc.golmar.es/search/manual/50121913
G 2
B
MONITOR
a
h
b
i
c
d
j
k
e
l
MicroSD card
(Max. 16GB
i
Class 10)
h
Monitor status light:
Standby: Light fixed (low intensity).
Call: Light blinking.
Communication: Light fixed.
Missed call: Low and variable intensity light.
2-apartment kit
DIP 6: Configures the end of line. Leave in the ON position in monitors
APARTMENT 1
APARTMENT 2
where the video cable terminates. Others set to OFF.
PENTHA
PENTHA
DIP 1 to DIP 5: Sets the monitor address (addresses 0 to 31).
The switches set to OFF have a zero value.
The values of the switches set to ON are shown in the table below.
The monitor code is the sum of the values of the switches set to ON.
( )
1
CODE 0
CODE 16
Table of values
Switch
nº: 1
Value when ON
Surf
ac
e
4 30
x
3
e.
7" TFT colour screen.
f.
'Do not disturb' mode LED.
g.
'Divert call' mode LED.
h.
Vertical wiring entry.
i.
Connector fixings.
j. Con ector.
n
k.
DIP switch.
l.
Bus connection terminals.
Building
ON
DIP
2
3
4
5
1
2
3
4
5
6
: 1
2
4
8 16
E
xa
mpl : 0 + 0+4+0+16 = 20
e
Embedding box
Screws supplied with
the embedding box.