Preventive maintenance

11. Preventive maintenance

11.1. Residual current devices

It is recommended to carry out annual checks of the residual current device of the station. To do so, press the
RESET button on the device and wait for the unit to be reset.
To access the protections in the INGEREV GARAGE Wall charging stations, open the front cover.
To access the protections in the INGEREV GARAGE Basic and INGEREV GARAGE One charging stations, remove
the lower cover.
Any worker who accesses the inside of the charging station must have the proper training from the
company (charging station operator) and must be authorized to carry out such operations.

11.2. Ground connection

It is recommended to carry out an annual revision of the proper connection of the metal casing and other metal
components on the outside of the charging station with the installation ground conductor.
Any worker who accesses the inside of the charging station must have the proper training from the
company (charging station operator) and must be authorized to carry out such operations.
ABA2021IQM01_A - Installation and Operation Manual