Thank you for buying a ROBLIN product which has been manufactured to the highest quality standards
to meet your requirements.
We recommend you carefully read this booklet in which you will find instructions for installation, hints for
use and maintenance.
The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descrip-
tions of individual features that do not apply to your specific appliance.
1
ELECTRICAL
•
This cooker hood is fitted with a 3-core mains cable with a standard 10/16A earthed plug.
•
Alternatively the hood can be connected to the mains supply via a double-pole switch having 3mm
minimum contact gap on each pole.
•
Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on
the rating plate inside the cooker hood.
•
Technical Specification: Voltage 220-240 V, single phase ~ 50 Hz / 220 V - 60Hz.
2
INSTALLATION ADVICE
•
Ensure the cooker hood is fitted in compliance with the recommended fixing heights.
•
It is a possible fire risk if the hood is not sited as recommended.
•
To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles
on the underside of the cooker hood and the cooker hood should be positioned away from doors and
windows, which will create turbulence.
•
Ducting
•
If the room where the hood is to be used contains a fuel-burning appliance such as a central
heating boiler then its flue must be of the room sealed or balanced flue type.
•
If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to
the room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional
measurement equivalent to the diameter of the ducting being fitted, if not larger.
•
The ducting system for this cooker hood must not be connected to any existing ventilation system,
which is being used for any other purposes or to a mechanically controlled ventilation ducting.
•
The ducting used must be made from fire retardant materials and the correct diameter must be
used, as incorrect sized ducting will affect the performance of this cooker hood.
•
When the cooker hood is used in conjunction with other appliances supplied with energy other than
electricity, the negative pressure in the room must not exceed 0.04 mbar to prevent the fumes from
combustion being drawn back into the room.
•
The appliance is for domestic use only and should not be operated by children or people who are
infirm without supervision.
•
This appliance must be positioned so that the wall socket is accessible.
•
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
3 FITTING
Any permanent electrical installation must comply with the latest regulations concerning this type of instal-
lation and a qualified electrician must carry out the work. Non-compliance could cause serious accidents
or injury and would deem the manufacturers guarantee null and void.
IMPORTANT - The wires in this mains lead are coloured in accordance with the following code :
green / yellow : earth
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows.
blue : neutral
brown : live
GB
5