Use multi-conductor shielded twisted pair cable specially made for ATEX environment.
Max length RS485: 3 280 ft / 1000 m at 9600 baud (SYT2 AWG24 recommended)
Max length RS232: 49.21 ft / 15 m (SYT2 AWG24 recommended)
TTL:
Use a multi-conductor shielded untwisted.
2 cable AWG24 – 30 m / 98.4 ft max
4 cables AWG24 – 60 m / 196.9 ft max
6 cables AWG24 – 100 m / 328.1 ft max
As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on
▪
their radiation level and the proximity of the reader.
▪
Connect the ground to the box of the reader.
By design, the reader can be installed indoors and outdoors.
▪
▪
Connect the wires or the connector of the reader BEFORE powering on.
Use a plug for unused connector:
▪
Type: RFID TAG READER
Temperature : -20°C to +70°C / -4°F to +158°F
Connectors: 2 cables glands PE PAP-R0 M20 for blinded cable 10-19 mm.
EC type examination certificate: BKI 08 ATEX 0048
Type approved: GUB
Ex II 2 GD
Marking: Ex d IIC T5 ExtD A21 T100°C IP66
Homologation: ATEX (EN60079) & IECEx
Type: RFID TAG READER
Temperature : -20°C to +50°C / -4°F to +122°F
Connectors: 2 cables glands PE PAP-R0 M20 for blinded cable 10-19 mm.
EC type examination certificate: BKI 08 ATEX 0048
Type approved: GUB
Ex II 2 GD
Marking: Ex d IIC T6 ExtD A21 T85°C IP66
Homologation: ATEX (EN60079) & IECEx
Type approved: PAP-R0 M20
II 2 GD
Marking: Ex d IIC – Ex e II – Ex tD A21
Degree of protection: IP66 level
1
2-3-4
Inner sealing ring for armored cable
5
6
Armour clamping ring for armored cable
7
8-9
10
11
12
13
Chamber will be filled with sealing when cable gland is completed assembled.
*
ATEX & IECEX reader
Installation procedure
ATX characteristics Flameproof Enclosure
ATX2 characteristics Flameproof Enclosure
Cable gland body
Armour clamping cone
Gland barrel
Internal sealing ring
Anti rubbing washer
Cable gland head
O-Ring seal
*Chamber for sealing
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1104X03 - Page 1 sur 18 - Ed. 20/01/2021
Lecteur ATEX & IECEX
Notice d'installation
Recommended Cables
2 cable AWG20 – 50 m / 164. ft max
4 cables AWG20 – 100 m / 328.1 ft max
Recommendations
Ref STid: BOUCHON_N
Characteristics Cable gland
Ø internal
Ø external
Thread C
ATEX & IECEX lectores
Manual de instalación
Min
Max
4 mm / 0.157 in
10 mm / 0.394 in
10 mm / 0.394 in
15 mm / 0.591 in
ISO: M20
NPT: ½"
US
FR
ES