Enlaces rápidos

OEM Module
MS2 13.56 MHz
MS2S 13.56 MHz & Blue
Installation instructions
MS2S-A
7
6
5
4
3
2
1
MS2-A
7
6
5
4
3
2
1
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC EN UL 60950-1 Ed2) or type ES1, PS1 (according to IEC EN UL 62368-1) for the
main supply.
Main power supply:
Max. consumption at 5 Vdc:
Regulated output:
Communication:
Asynchronous RS232 serial link with TTL levels / TTL (Wiegand / Clock and Data).
Connector output:
HE14 male 7 pins.
Pull-up resistors:
For Data signals, pull-up resistors are connected internally to 3.3 Volts.
Protection:
Tropicalized electronic board.
▪ The supply voltage at the reader's connector should be between +4.5 Vdc and +9 Vdc.
▪ We recommend using a filtered and regulated power supply.
▪ As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level
and the proximity of the reader.
▪ Maximum distance between reader and the controller board: 500 mm.
▪ Recommended distance between two readers: parallel plane: 11.8 in – same plane: 15.8 in – perpendicular plane: 11.8 in.
▪ Recommended distance between two Blue readers: 78.74 inch either plan.
▪ Readers installed on a metal surface causes a very strong reduction in reading distance.
▪ Connect the wires or the connector of the reader BEFORE powering on.
▪ The signals are of the RS232-TTL form, do not connect the reader directly to a RS232 serial port.
▪ Operating temperature: -22°F to 158°F / -30°C to +70°C
Read only readers (R31 & S31)
The operating mode can be programmed by a configuration card.
The initial status of the input "Switch" is memorized when the power supply
is turned on.
If the status becomes different from the initial status, the reader is wrenched
and the wrenching signal will be emitted on the "Data/ D1" line.
This function is configurable via a configuration card (SCB).
Readers are configurable with the SCB configuration card or virtual
configuration card created with SECard.
- If the SCB is compatible with the firmware: the LED lights green for 1 s.
- If the SCB is not compatible with the firmware: the LED lights red for 1 s.
- If the SCB key is different from the reader 's key: no reaction.
Caution: set your reader with your own company key.
1. Initialization: activation of the white LED for 10 s.
2. Indication of the reader type: activation of the LED according to the color
code: Cyan = +5, Magenta = +1.
3. Indication of the firmware version: activation of the LED according to the
color code: Red = +10, Orange = +5, Green = +1.
4. Waiting firmware update: the orange LED flashes for 5 s.
5. Activation of the default LED (fixed blue if no customer specific
configuration).
STid reserves the right to make change without notice, for the purpose of product improvement.
Module OEM
MS2 13,56 MHz
MS2S 13,56 MHz & Blue
Notice d'installation
Range: +4.5 Vdc to +9 Vdc
MS2: 180mA
MS2S: 190mA
3.3 Vdc
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1140A02- Page 1 sur 6 - Ed. 02/12/2019
Products / Connection
Pin
Wiegand
7
6
5
Clock
4
3
2
1
Power supply characteristics
Typical: 5 Vdc
Characteristics
Precautions for installation
LED
The operating mode can be controlled by the SSCP commands.
Switch input
The initial status of the input "Switch" is memorized when the power supply
is turned on.
If the status becomes different from the initial status, the reader is wrenched
and the reader will perform the operations configured with the SSCP protocol.
Reader configuration
Blue-NFC settings can be configured by SCB RW configuration badge created
with SECard v3.3 minimum or by the SSCP commands.
Caution: set your reader with your own company key.
Powering-up the readers
1. Activation of the white LED for 1 s.
Módulo OEM
MS2 13.56 MHz
MS2S 13.56 MHz & Blue
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
Type
Clock & Data
RS232-TTL
Not Connected
Switch
Clock
D1
Data
D0
Code
+Vcc (+4.5 Vdc to +9 Vdc)
0 Vdc
Read / Write readers (W31)
US
FR
ES
Rx
Tx
NC

Publicidad

loading

Resumen de contenidos para Stid MS2S-A

  • Página 1 5. Activation of the default LED (fixed blue if no customer specific configuration). © STid - 20 PA des Pradeaux FR13850 Gréasque – NI1140A02- Page 1 sur 6 - Ed. 02/12/2019 STid reserves the right to make change without notice, for the purpose of product improvement.
  • Página 2 ESR-RECYLUM, to which STid adheres and to which it has transferred its regulatory responsibilities as a Producer. STid recommends that owners of used equipment who wish to dispose of it return it as WEEE by contacting ESR / RECYLUM in order to benefit from the solutions at no additional cost of collecting and recycling used equipment.
  • Página 3: Précautions D'iNstallation

    5. Activation de la LED par défaut (bleu fixe si pas de configuration client spécifique). © STid - 20 PA des Pradeaux FR13850 Gréasque – NI1140A02- Page 3 sur 6 - Ed. 02/12/2019 STid reserves the right to make change without notice, for the purpose of product improvement.
  • Página 4 Conformément aux dispositions du code de l’environnement (Sous-section 1, Paragraphe 1, art R 543-171 et suivant), STid finance la filière de collecte, de dépollution et de recyclage des DEEE mise en place par ESR-RECYLUM à laquelle STid a adhéré et à laquelle elle a transféré ses obligations réglementaires de Producteur.
  • Página 5 5. Activación del LED predeterminado (fijo azul si no hay una configuración específica del cliente). © STid - 20 PA des Pradeaux FR13850 Gréasque – NI1140A02- Page 5 sur 6 - Ed. 02/12/2019 STid reserves the right to make change without notice, for the purpose of product improvement.
  • Página 6 Declaración de conformidad STid declara que el lector MS2-A/MS2S-A cumple las exigencias esenciales de la Directiva RED 2014/53/UE y RoHs 2011/65/UE. Una copia de nuestra declaración está disponible enviando una solicitud a qualite@stid.com. Lector MS2S cumple con la Sección-15 de la FCC. Su funcionamiento está sujeto a las dos condiciones siguientes: 1) Este aparato no debe provocar interferencias nocivas.

Este manual también es adecuado para:

Ms2-a