C
SX M-LINK
OCKPIT
14.
Setting up a new model
Model type: ACRO
14.6.
Activating flight phases
14.10.1.
What is possible with flight phases?
NEW:
The C
SX M-LINK allows you to set the value for
OCKPIT
EXPO separately for each flight phase. The value is
set using the same method as for Dual-Rate
(
14.10.2.)
18.
Managing model memories
Menu: MEMO
NEW:
Two additional menus:
• Transmitting Fail-Safe settings to the receiver
Menu: SENDFS
• Activating / disabling Fast-Response
(14 ms pulse rate)
Menu: F-RESP
18.6.
Transmitting the Fail-Safe positions
to the receiver
Menu: (
) SENDFS
MEMO
All M-LINK receivers feature Fail-Safe. If no valid signal
is picked up, the servos move to a user-programmable
position after a certain waiting time. The following
methods of determining these positions are available:
1. The SET button on the receiver
Use the transmitter to move all the servos to the de-
sired positions, then briefly press the SET button on
the receiver (
see receiver instructions).
SX M-LINK SENDFS menu
2. C
OCKPIT
How to access the SENDFS
to MENU,
to MEMO,
to SENDFS,
Briefly press the 3-D digi-adjuster ( ).
The 0 on the screen flashes.
Use the transmitter to move all the receiver outputs
(servos, speed controller) to the desired positions, and
hold them there.
Now turn the 3-D digi-adjuster to the right
It makes no difference whether you turn it by one or
more clicks. The number in the bottom line now runs
through the range 0 to 7, indicating the transmission of
the seven Fail-Safe positions to the receiver. When the
transmission is complete, the 0 appears again, this
time not flashing.
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
18.6.
18.7.
:
(SETUP appears),
(GO TO appears),
.
You can now quit the menu by turning the 3-D rotary
control to the left
via EXIT, or with a long press
on the 3-D digi-adjuster.
18.7.
Activating / disabling Fast Res-
ponse (fast frame rate)
) F-RESP
Menu: (
MEMO
The C
SX M-LINK can generate servo signals
OCKPIT
with two different frame rates.
•
21 ms (default, Fast-Response = 0)
•
14 ms (Fast-Response = 1)
The servo signals are repeated every 14 / 21 ms.
NOTE:
The shorter frame rate (14 ms) may cause analogue
servos to run jerkily or oscillate.
At the 21 ms frame rate all servos should work without
problem; that is why this setting is programmed as the
default value. F-RESP can be set separately for each
model memory.
How to access the menu F-RESP:
to MENU,
to MEMO,
to F-RESP,
Press the 3-D digi-adjuster briefly ( ).
The 0 in the display flashes.
You can now use the 3-D digi-adjuster to select your
preferred mode of operation:
0
= 21 ms
1
= 14 ms
You can quit the menu by turning the 3-D rotary control
to the left
via EXIT, or with a long press
D digi-adjuster.
(SETUP appears),
(GO TO appears),
on the 3-
Seite 8/9