10.1 Cleaning unit

Fault
Pneumatic motor does
not run
Stroke does not work
Insufficient cleaning
Torch parts are
damaged
Tab. 16
Troubleshooting

10.2 TSi injection unit

Fault
No injection
Too much/too little
spray mist
Too little spray mist
No spray mist
Tab. 17
Troubleshooting for the injection unit
BAL.0109 • 2020-12-15
Cause
• Compressed air supply/hose connection
interrupted
• Solenoid valve Y2 does not switch
• Valve actuator does not move
• Solenoid valve Y1 does not switch
• Reamer defective or blunt
• Wrong equipment parts
Cause
• Check the fill level
• Compressed air supply/hose connections
interrupted
• Mechanically operated injection valve Y4
does not switch
• Anti-spatter fluid is empty
• Metering quantity incorrectly adjusted
• Injection time too short
• Operating pressure too low
• Operating pressure too low
10 Troubleshooting
Troubleshooting
• Check all supply lines leading to the motor,
solenoid valve Y2 and threaded fittings
• Motor defective; replace
• Check the signal output of the robot control
• Replace solenoid valve
• Check the supply lines to the valve and
threaded fitting
• Replace the reamer
• Check torch-dependent parts
• Check the immersion depth of the torch
Troubleshooting
• Top up the anti-spatter fluid
• Check all supply lines leading to the
cylinder and threaded fittings
• Replace mechanically operated injection
valve Y4
• Replace or refill bottle
• Adjust the throttling screw
• Check injection time (torch dwell time in
injection unit)
• Check the operating pressure
• Check the operating pressure
EN - 25