10.2 STANDBY FUNCTION
During operation (i.e. when the stove is on and in steady operating conditions) the stove can be switched off
when reaching the set room temperature (SET ROOM T.) and start again when reaching the set minimum room
temperature (START TEMP.).
To enable this function, go to the "STOVE SETTINGS MENU" following the "Procedure for accessing the menus"
described in paragraph 7.3 and press
and then press
Two parameters can be set:
7KH ¿UVW 212)) HQDEOHV RU GLVDEOHV WKH IXQFWLRQ
7KH VHFRQG GH¿QHV WKH WHPSHUDWXUH IRU UHVWDUWLQJ WKH VWRYH
When this function is active, the display shows the " " symbol.
"STAND-BY" is displayed when the room temperature is higher than the set "START TEMP.".
10.3 FROST PROTECTION FUNCTION
When the stove is off this function ensures the stove maintains the set room temperature (useful at night).
To access this function go to the "STOVE SETTINGS MENU" using the "Procedure for accessing the menus"
described in paragraph 7.3 and press
T." using the
7KLV PHQX KDV MXVW RQH SDUDPHWHU ZKLFK FDQ EH VHW WR ³2))´ IXQFWLRQ GLVDEOHG RU DOWHUQDWLYHO\ D WHPSHUDWXUH
value (between 3° and 20°C) representing the temperature below which the stove will start.
When this function is active, the display shows the " " symbol.
"NIGHT STAND-BY" is displayed when the room temperature is higher than the set "NIGHT SET T".
10.4 "ECONOMY" FUNCTION
This is used to set the stove's maximum operating output in automatic mode. The set power level will never be
exceeded, thus keeping fuel consumption under control.
10.5 RESTARTING AFTER A POWER FAILURE
In the event of momentary power failures, the stove will restart automatically when power returns, if the conditions
DUH ULJKW ,I VXFK FRQGLWLRQV DUH QRW IXO¿OOHG WKH GLVSOD\ ZLOO VKRZ ³%ODFN 2XW $ODUP´ DQG WKH VWRYH PXVW EH UHVHW
manually as described in chapter 12.
10.6 READING THE OPERATING HOURS
The display can show total stove operating hours or the number of hours remaining before recommended
maintenance is required (to be performed by the Service Centre).
Pressing and holding the
the
button will display the REMAINING HOURS for a few moments.
10.7 PELLET LEVEL FUNCTION
The pellet stove is provided with a device for the detection of the reserve level of the pellet tank. When this value
is reached, the words 'LOW PELLET' will be displayed cyclically and an acoustic signal will be uttered.
:H VXJJHVW \RX WR UH¿OO WKH SHOOHW WDQN EHIRUH LW LV FRPSOHWHO\ HPSW\
10.8 OPERATION WITH ROOM THERMOSTAT
After having connected the room thermostat, when this is activated the stove will go to the lowest power
level (minimum output) while otherwise maintaining standard operation. The display will show the message
³7+(50267$7 21´ RU DOWHUQDWLYHO\ WKH WZR WHPSHUDWXUH YDOXHV ZLOO ÀDVK
10.9 "EASY CLEAN" FUNCTION
This function is used to clean the stove by reducing the amount of ash dispersed in the room.
'XULQJ WKLV RSHUDWLRQ WKH ÀXH JDV IDQ RSHUDWHV DW PD[LPXP VSHHG WKXV SUHYHQWLQJ DVK IURP OHDYLQJ WKH ¿UHER[
It can only be activated when the stove has cooled down completely and is off.
When the stove is OFF, press the
switch off automatically after a preset cycle).
To stop the operation manually, press the
60/164
USE AND MAINTENANCE
.
button.
button will display the TOTAL HOURS for a few moments, while pressing and holding
EXWWRQ IRU VHFRQGV WKH ÀXH JDV IDQ ZLOO VWDUW DW PD[LPXP VSHHG DQG ZLOO
OFF
. Use the arrow buttons to scroll until the display shows "STAND-BY"
. Use the arrow buttons to scroll the menu and select "NIGHT SET
button.
OFF
cod. 00 477 1480 - 12/2012 - Palazzetti - PN - Italy