Max. Allowable Input Current: 10A.
(For measurements > 2A: measurement duration
< 10 secs, and interval > 15 minutes.).
4. RESISTANCE
RANGE
200
2000
20k
200k
2000k
Max. open circuit voltage: about 3V.
5. DIODE AND BUZZER
Diode: Testing Voltage about 2.8 V, current about 1mA. The
approximate forward voltage drop in mV will be displayed.
Buzzer: The buzzer will sound when the resistance is less
than about 50 .
6. BATTERY TEST
Range
The working voltage of the
1.5V
battery will be displayed on
the LCD, so that the quality
9V
of the battery can be judged.
GENERAL SPECIFICATION
• Display:
• Polarity:
• Over range indication:
• Operating environment:
• Storage temperature:
• Battery:
• Low battery indication: "
4
RESOLUTION
0.1
1
10
100
1k
Description
Test Condition
The working current is about 20mA
The working current is about 5mA
3-1/2 digits LCD with a max.
reading of 1999
Auto polarity indication.
Only figure "1" on the display.
32ºF to 104ºF (0ºC - 40ºC);
<75%RH.
14ºF to 122º F (-10°C to 50°C)
<85%RH.
9V 6F22
" or "BAT" appears on
the display.
ACCURACY
± (1.2% + 5)
± (1.0% + 5)
± (1.2% + 5)