Maintenance - Abus FUBE50061 Manual De Instalacion Y Uso

Interruptor de llave inalámbrico
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

10. Maintenance

Put your Secvest wireless alarm panel into installer mode. You can now
open the wireless key switch without a sabotage alarm being triggered.
Replace the battery with another battery of the same type.
In the case of an external power supply being used, please remember to
replace the batteries before their expiry date.
If the batteries need to be replaced, the alarm control panel will display the
error message "FKBDT == batt low". In this case, the batteries should be
replaced by an installer.
The internal buttons must undergo functional testing every year, and the
key switch must also be cleaned.
With FUAA50XYZ
In order to launch functional testing of the internal buttons, ensure that the
system is not currently in operation. In installer mode, select "Test 
wireless control panel wireless control panel 01-08".
Select the wireless control panel required. The display now shows "Press
key to test". Turn the key to the right (arm) or to the left (disarm).
The display now shows the programmed user code followed by the internal
button that was pressed, e.g. "1234A" or "1234B".
Clean the outside of the housing. Do not use any form of solvent or
cleaning agent.
EN 26

Publicidad

Tabla de contenido
loading

Tabla de contenido