7
CALLING STATION INSTALLATION
Remove the metal front panel of the door unit by loosening the screw on the bottom using the specific tool
provided.
Check that the rubber seal is present on the back of the door panel. You will find it in the kit box if it is not
already applied. Important note: align the cuts for passing the wires through the rubber seal with those of
the protective seal.
Position the panel at the recommended height and connect the wires to the terminal board.
Extract the name tag as shown in figure 2 to customise the calling button.
Terminal board
7.1
DESCRIPTION OF TERMINAL BOARD
L1
Terminals for connecting door unit to video door phone
L2
SE1
Connection for electric lock 12Vac or 12Vdc – max 15VA
SE2
AP1
Connection for electric lock local opening button
AP2
LBT20005
23