Parts needed:
Check local codes. Check existing electrical supply and venting, and read
"Electrical Requirements" and "Venting Requirements" before purchasing
parts.
Mobile home installations require metal exhaust system hardware,
available for purchase from the dealer from whom you purchased your
dryer. For further information, please reference the "Assistance or Service"
section of your "Use and Care Guide."
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers.
The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum.
■
The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m)
long. The wires that connect to the dryer must end in ring terminals
or spade terminals with upturned ends.
A UL listed strain relief.
■
Location Requirements
You will need:
A location allowing for proper exhaust installation. See "Venting
■
Requirements."
A separate 30 amp circuit.
■
If you are using power supply cord, a grounded electrical outlet
■
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of 200 lbs.
■
(90.7 kg). The combined weight of a companion appliance should
also be considered.
Level floor with maximum slope of 1" (25 mm) under entire dryer.
■
(If slope is greater than 1" [25 mm], install Extended Dryer Feet Kit,
Part Number 279810.) If not level, clothes may not tumble properly
and automatic sensor cycles may not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At lower
temperatures, the dryer might not shut off at the end of an automatic
cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation
of the dryer in garages, closets, mobile homes, or sleeping quarters.
Contact your local building inspector.
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
43
/
"
3
8
(1102 mm)
*27
/
"
3
4
(705 mm)
29"
(737 mm)
A
C
A.Wide opening side-swing door
B. Wide opening hamper door
* Most installations require a minimum 5½" (140 mm) clearance behind
the dryer for the exhaust vent with elbow. See "Venting Requirements."
Minimum spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
Additional spacing should be considered for ease of installation and
■
servicing.
Additional clearances might be required for wall, door, and floor
■
moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
■
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in
■
the top and bottom of the door are required. Louvered doors with
equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
■
Minimum Installation Spacing
18"*
(457 mm)
1"
29"
1"
(25 mm)
(737 mm)
(25 mm)
(25 mm)
A
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
*Additional spacing is recommended.
Mobile home – Additional installation requirements
This dryer is suitable for mobile home installations. The installation must
conform to the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD Part 280) or the Canadian
Manufactured Home Standard CAN/CSA-Z240 MH.
Metal exhaust system hardware, available for purchase. For further
■
information, please reference the "Assistance or Service" section of
your "Use and Care Guide."
Special provisions must be made in mobile homes to introduce
■
outside air into the dryer. The opening (such as a nearby window)
should be at least twice as large as the dryer exhaust opening.
22¾"
(578 mm)
43
/
"
3
8
(1102 mm)
*27
/
"
3
4
(705 mm)
29"
(737 mm)
B
D
14" max.*
48 in.
2
*
(356 mm)
2
(310 cm )
*
24 in.
2
2
(155 cm )
1"*
27
¾"
(705 mm)
B
C
13¾"
(349 mm)
3"*
(76 mm)
3"*
(76 mm)
5