29
R/W Control mode
30
R/W proportional factor
31
R/W integral factor
32
R
last alarm recorded
33
R/W Braking Joules
34
R/W Modbus code
35
R/W Stop power for dry operation stop
36
R/W clock h
37
R/W clock l
38
R/W magnetization
39
R/W T R fault stop
40
R/W modbus communication
41
R/W baud rate
42
R
status rotation
43
123/137
0
0
0
0
J/100
1
1
%Pn
20
seconds*0x10000
0
seconds
0
%
80
0
1
bit/s
0
0
NEO-WiFi – manual - ES
0 = Speed;
1 = Speed+Encoder;
4
2 = Ventilation;
3 = Compressor;
4 = HP Pump.
100
100
6539
127
127
Inverter code in Modbus communication
100
To calculate follow this calculation:
minutes * 60= result
result + (Hour * 60 * 60)= result 1
result 1 + (Day * 60 * 60 * 24)= result 2
result 2 + (Month * 60 * 60 * 24 * 32) =result 3
0xffff
result 3 + (Year * 60 * 60 * 24 * 32 * 13) =result 4
For the year write only the last two digits, for example 2014 must be
14
result 4 /65536= clock h without decimals
If there are problems during calculation, please download the
spreadsheet automatically from www.motive.it
To calculate follow this calculation:
minutes * 60= result
result + (Hour * 60 * 60)= result 1
result 1 + (Day * 60 * 60 * 24)= result 2
result 2 + (Month * 60 * 60 * 24 * 32) =result 3
result 3 + (Year * 60 * 60 * 24 * 32 * 13) =result 4
0xffff
For the year write only the last two digits, for example 2014 must be
14
result 4 / 65536 = clock h without decimals
result 4 – (clock h*65536 )= clock I without decimals
lf there are problems during calculation, please download the
spreadsheet automatically from www.motive.it
120
0=OFF, 1=ON;
When this function is ON, it switches off the motor if:
-The T/R radio communication between keypad and NEO is missing
1
for more than 5 seconds;
-The modbus communication (Variable 40=2) loses the signal from
serial port RS485;
0 =OFF, 1=ON+KEY, 2=ON
OFF = programming and operation only from keypad
ON+KEY = programming from modbus and operation from keypad
2
(External remote wired control/speed signal are included),
ON=motor is commanded by Modbus
ON = programming and operation only from modubs
0 = 4800
1 = 9600 (Default)
3
2 = 14400
3 =19200 bit/s
It's the position set on selector, received from the keyboard
0=OFF
2
1=direction 1
2=direction 2
REV18-GEN20