Product Description - Ingersoll Rand 15318371 Información De Seguridad Sobre El Producto

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN

Product Description

The Air line Filters, Regulators, Lubricators, Filter/Regulators and Combination Units are intended
for use in industrial compressed air systems only. No other use is recommended.
General Product Safety Information
Read and understand this manual before operating this product.
It is your responsibility to make this safety information available to others that will operate
this product.
Failure to observe the following warnings could result in injury.
Do not use for liquids, life support system or compressed gasses other than air.
Always install, operate, inspect and maintain this product in accordance with all applicable
standards and regulations (local, state, country, federal, etc.).
This product contains high pressure air when in use.
Only Service Technicians that are qualified to work on pressurized pneumatic systems should
install, maintain or repair this system.
Detailed Installation and Maintenance Instructions are available in an Installation and
Maintenance manual on-line at fluids.ingersollrand.com.
Product Safety Information - Installation
Install in an accessible location where product is safe from damage or puncture.
Do not expose this product to direct sunlight, radiant heat, heavy vibration, shock, corrosive
gases, chemicals, vapors from organic solvents, water, salt water or steam.
Polycarbonate Bowl: To avoid rupture that can cause personal injury or property damage.
-
Do not expose internally or externally to incompatible chemicals;
Thinner, Certain Alcohols, Aniline, Carbon Tetrachloride, Chlorinated Hydrocarbons,
Chloroform, Esters, Ethyl Acetate, Kerosene, Ketones, Lactic Acid, Nitric Acid, Nucleic
Acid, Organic solvents, Chemical Solvents, Paints and fumes, Trichloroethylene,
Compressor Oils containing Ester based additives, Synthetic Oils and fumes with any of
the above substances.
Use a metal bowl in applications where a polycarbonate bowl might be exposed to
substances or conditions that are incompatible with polycarbonate.
Be sure all hoses, accessories and fittings are the correct size, are tightly secured and rated
above the maximum compressed air inlet pressure.
Ensure an accessible emergency shut off valve has been installed in the air supply line, and
make others aware of the location.
Install Filter, Regulator then Lubricator or Filter/Regulator and Lubricator with air flow in
direction of arrows located on product.
All maintenance instructions must be followed to ensure proper and safe system operation.
Always wear eye protection when operating or performing maintenance on this product.
Do not exceed the maximum rated temperature or maximum rated pressure for the product.
This may result in hazardous situations including rupture of fittings, hoses, bowls or other
parts of the system.
EN-1
WARNING
WARNING
15318371_ed1

Publicidad

Tabla de contenido
loading

Tabla de contenido