FENCE LEAD AND GROUNDING CHECK
Tip 2
Check grounding ‑> measure
voltage directly at the ground rod!
Tip 6
38
1
Check fence voltage at the
end of the fence!
Is voltage over 6000V?
YES
Switch off the energiser,
connect to fence and switch
on again
Use fence tester to check
voltage on fence. Is it more
than 2.5/4 kV?
NO
2
Is the voltage on the
grounding rod more than
1000 V?
YES
Improve grounding
INSTRUCTION MANUAL VOSS.FARMING SUNNY 800
Check the fence
Tip 5
NO
Fence connection cable is
defective.
YES
Problem solved
Check the grounding
Tip 3
Fault is on the fence. Voltage
NO
loss due to poor connections
(knots, corroded connectors,
conductor materials)
Use fence tester to check
voltage on fence. Is it more
than 2.5/4 kV?
YES
Everything is fine
Tip 7
NO
42088 | 01 | 2021 | V3