Gas and Electric Supply Zones
NOTICE:
— If not already present, install gas shut-off valve in an
easily accessible location.
— Make sure all users know where and how to shut off
the gas supply to the range.
— Any opening in the wall behind the appliance and any
opening in the floor under the appliance must be
sealed.
This appliance is manufactured ready to install with a
supplied 4-wire cord set with plug attached to the
appliance. The unit must be properly grounded. Refer to
"Step 6: Electrical Requirements, Connection & Grounding"
on page 12 for details.
The range must be connected only to the type of gas
for which it is certified. If the range is to be connected to
propane gas, ensure that the propane gas supply tank is
equipped with its own high pressure regulator in addition to
the pressure regulator supplied with the range (See "Step
5: Gas Requirements and Hookup" on page 11.).
NOTE: The range is designed for flush installation to the
back wall. For a successful installation, it may be
necessary to reposition the gas supply line and the
electrical cord as the range is pushed back to its final
position.
--
SUGGESTION: This may be accomplished by carefully
pulling on a rope or twine looped around the gas or
electrical supply line as the range is pushed back into
its final installed position.
30" Range Width
30" Range Width
30" Range Width
GAS & ELECTRICAL SUPPLY ZONE
4⅜"
(111 mm)
5¾"
5¾"
5¾"
7
7
7
18
18
18
/
/
/
16
16
16
(146 mm)
(146 mm)
(146 mm)
(468 mm)
"
"
"
"
5
13
/
16
(148 mm)
Figure 4: Gas & Electrical Supply Locations
Electrical Supply
Installation of the range must be planned so that rough-in
of terminal block for the receptacle or conduit connection
will allow maximum clearance to the rear of the unit.
When the power supply cord or conduit is connected to the
mating receptacle or terminal block cover, the combined
plug/receptacle or terminal block cover/conduit connector
should protrude no more than 2'' (51 mm) from the rear wall
)
(see Figure 5.
Power Cord & Receptacle
2" (51 mm) maximum
when plugged in
Refer to Figure 9 on page 13 for location of terminal block
on unit. To minimize binding when the unit is connected to
the receptacle or terminal block, orient the receptacle or
conduit connector, and slide back into position.
2" (51 mm) max.
2" (51 mm) max.
2" (51 mm) max.
protrusion from wall
protrusion from wall
protrusion from wall
for gas or electrical
for gas or electrical
for gas or electrical
supply.
supply.
supply.
Junction Box & Conduit
2" (51 mm)
maximum
Figure 5: Wall Connection
English 8